Off-pump coronary artery surgery with the Coronéo Cor-Vasc stabilizing device: clinical experience of 141 patients

Numerous devices have been successfully introduced in off-pump coronary artery bypass graft (OPCABG) surgery, most of them being disposable tools based on suction stabilization. Coronéo Cor-Vasc is a reusable system combining suction positioning with compression stabilization. The purpose of this st...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular medicine (Hagerstown, Md.) Vol. 11; no. 5; p. 381
Main Authors Spina, Amedeo, Benussi, Bernardo, Pappalardo, Aniello, Forti, Gabriella, Tognolli, Umberto, Gabrielli, Marco, Gatti, Giuseppe, Zingone, Bartolo
Format Journal Article
LanguageEnglish
Published United States 01.05.2010
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Numerous devices have been successfully introduced in off-pump coronary artery bypass graft (OPCABG) surgery, most of them being disposable tools based on suction stabilization. Coronéo Cor-Vasc is a reusable system combining suction positioning with compression stabilization. The purpose of this study was to analyze our experience in OPCABG with the Cor-Vasc system. Between March 2001 and May 2008, 141 patients (age = 71.1 +/- 7.5 years) underwent OPCABG surgery using the Cor-Vasc system, representing 6.3% of the case volume of isolated coronary artery bypass graft surgery in the same period. Eighty-eight patients (62.4%) underwent surgery on an urgent basis. In 95 patients (67.4%), the OPCABG option was selected after finding a diseased ascending aorta at intraoperative epiaortic ultrasound. Among 334 anastomoses (mean = 2.4 +/- 1 per patient), 242 (95 patients) were fashioned with bilateral and 54 (46 patients) with single internal thoracic artery, respectively. In 89.4 and 73% of patients, a complete and a total arterial myocardial revascularization was achieved, respectively. There were two strokes (1.4%) and two myocardial infarctions (1.4%). Two patients died in the hospital (1.4%). Median ICU and in-hospital length of stay were 31.2 h and 10 days, respectively. In our experience, the use of the Cor-Vasc system, including the device-learning curve, was associated with low mortality and morbidity indexes in an aged population with a high risk of stroke. The system appeared to be sufficiently versatile and potentially cost-effective when compared with disposable devices.
ISSN:1558-2035
DOI:10.2459/JCM.0b013e328337993d