Validation of the AccuPoint Advanced ATP Hygiene Monitoring System for Sanitation Monitoring Through Detection of ATP from Stainless Steel Surfaces

The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'s system is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's e...

Full description

Saved in:
Bibliographic Details
Published inJournal of AOAC International Vol. 100; no. 2; pp. 537 - 547
Main Authors Viator, Ryan, Gray, R Lucas, Sarver, Ron, Steiner, Brent, Mozola, Mark, Rice, Jennifer
Format Journal Article
LanguageEnglish
Published England 01.03.2017
Subjects
Online AccessGet full text

Cover

Loading…
Abstract The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'s system is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's effectiveness by detecting organic residues remaining on surfaces and in liquids after cleaning. The system is composed of three primary components: an electronic luminometer, fully self-contained single-use samplers, and software. The system is designed to detect adenosine triphosphate (ATP) at set thresholds and to report the measurement in relative light units (RLU). These thresholds are established by a facility to reflect effective cleaning practices. The instrument compares the measured level of ATP with the established threshold and reports the results as pass, marginal, or fail. A linear dose-response in RLU was observed with pure analyte. In the matrix and microbial studies, detection levels varied depending on the matrix and microorganism tested. Independent laboratory trials confirmed pure analyte and matrix observations. Specificity testing of similar, yet different, compounds resulted in 0 RLU for all except 2'-deoxyadenosine 5'-triphosphate sodium salt, which showed markedly reduced reactivity when compared with ATP. Also, interference by these compounds was negligible. When disinfectant residues were evaluated for their effect on the test, cleaners increased RLU output to varying degrees. Stability testing showed consistent results between three independently manufactured lots and stable results through the 9 month shelf-life. Additionally, when three readers were compared using electronic light-emitting diodes as the light source, instrument variability was low (<3%). Robustness testing results provided evidence that temperature affects test performance more than shaking time, and sampler performance improves as the temperature increases to room temperature. These results provided evidence that the AccuPoint Advanced ATP Hygiene Monitoring System produces consistent and reliable data for the evaluation of sanitation program effectiveness on stainless steel surfaces in food processing and food service facilities.
AbstractList Abstract The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'ssystem is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's effectiveness by detecting organic residues remaining on surfaces and in liquids after cleaning. The system is composed of three primary components: an electronic luminometer, fully self-contained single-use samplers, and software.The system is designed to detect adenosine triphosphate (ATP) at set thresholds and to report the measurement in relative light units (RLU). These thresholds are established by a facility to reflect effective cleaning practices. The instrument compares the measured level of ATP with the established threshold and reports the results as pass, marginal, or fail. A linear dose–response in RLU was observed with pure analyte. In the matrix and microbial studies, detection levels varied depending on the matrix and microorganism tested. Independent laboratory trials confirmed pure analyte and matrix observations. Specificity testing of similar, yet different, compounds resulted in 0 RLU for all except 2′-deoxyadenosine 5′-triphosphate sodium salt,which showed markedly reduced reactivity when compared with ATP. Also, interference by these compounds was negligible. When disinfectant residues were evaluated for their effect on the test, cleaners increased RLU outputto varying degrees. Stability testing showed consistent results between three independently manufactured lots and stable results through the 9 month shelf-life. Additionally, when three readers were compared using electronic light-emitting diodes as the light source, instrument variability was low (<3%). Robustness testing results provided evidence that temperature affects test performance more than shaking time, and sampler performance improves as the temperature increases to room temperature. These results provided evidence that the AccuPoint Advanced ATP Hygiene Monitoring System produces consistent and reliable data for the evaluation of sanitation program effectiveness on stainless steel surfaces in food processing and food service facilities.
The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'s system is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's effectiveness by detecting organic residues remaining on surfaces and in liquids after cleaning. The system is composed of three primary components: an electronic luminometer, fully self-contained single-use samplers, and software. The system is designed to detect adenosine triphosphate (ATP) at set thresholds and to report the measurement in relative light units (RLU). These thresholds are established by a facility to reflect effective cleaning practices. The instrument compares the measured level of ATP with the established threshold and reports the results as pass, marginal, or fail. A linear dose-response in RLU was observed with pure analyte. In the matrix and microbial studies, detection levels varied depending on the matrix and microorganism tested. Independent laboratory trials confirmed pure analyte and matrix observations. Specificity testing of similar, yet different, compounds resulted in 0 RLU for all except 2'-deoxyadenosine 5'-triphosphate sodium salt, which showed markedly reduced reactivity when compared with ATP. Also, interference by these compounds was negligible. When disinfectant residues were evaluated for their effect on the test, cleaners increased RLU output to varying degrees. Stability testing showed consistent results between three independently manufactured lots and stable results through the 9 month shelf-life. Additionally, when three readers were compared using electronic light-emitting diodes as the light source, instrument variability was low (<3%). Robustness testing results provided evidence that temperature affects test performance more than shaking time, and sampler performance improves as the temperature increases to room temperature. These results provided evidence that the AccuPoint Advanced ATP Hygiene Monitoring System produces consistent and reliable data for the evaluation of sanitation program effectiveness on stainless steel surfaces in food processing and food service facilities.
Author Viator, Ryan
Mozola, Mark
Rice, Jennifer
Sarver, Ron
Steiner, Brent
Gray, R Lucas
Author_xml – sequence: 1
  givenname: Ryan
  surname: Viator
  fullname: Viator, Ryan
  organization: Neogen Corp., 620 Lesher Pl, Lansing, MI 48912
– sequence: 2
  givenname: R Lucas
  surname: Gray
  fullname: Gray, R Lucas
  organization: Neogen Corp., 620 Lesher Pl, Lansing, MI 48912
– sequence: 3
  givenname: Ron
  surname: Sarver
  fullname: Sarver, Ron
  organization: Neogen Corp., 620 Lesher Pl, Lansing, MI 48912
– sequence: 4
  givenname: Brent
  surname: Steiner
  fullname: Steiner, Brent
  organization: Neogen Corp., 620 Lesher Pl, Lansing, MI 48912
– sequence: 5
  givenname: Mark
  surname: Mozola
  fullname: Mozola, Mark
  organization: Neogen Corp., 620 Lesher Pl, Lansing, MI 48912
– sequence: 6
  givenname: Jennifer
  surname: Rice
  fullname: Rice, Jennifer
  organization: Neogen Corp., 620 Lesher Pl, Lansing, MI 48912
BackLink https://www.ncbi.nlm.nih.gov/pubmed/28118134$$D View this record in MEDLINE/PubMed
BookMark eNpNkc1rGzEQxUVJqPPRe09Fx1421Uj7paNJmybgkICdXBetdmTL7EqupC3478g_3DWOQ0_zGN77Dcy7JGfOOyTkK7CbosrZj63ySluXbqDMmAD4RC5A5nlWSc7PJs1KlglewYxcxrhlLIeS8c9kxmuAGkR-Qd5eVW87lax31BuaNkjnWo_PfqLSefdXOY0dna-e6f1-bdEhffTOJh-sW9PlPiYcqPGBLtW0PWL-M6w2wY_rDf2JCfXpxgFmgh_oMinreoxxUog9XY7BKI3xmpwb1Uf88j6vyMvdr9XtfbZ4-v1wO19kmkuZsg5l1dZYlAVXphQtk6ZAqIvKsFa2UtZStHnLoQAmcs1RVwJyUWjDoALgtbgi34_cXfB_RoypGWzU2PfKoR9jA3U54YSQBys7WnXwMQY0zS7YQYV9A6w5VNGcqmigbA5VTJFv7_SxHbD7CJx-L_4BBz-JdA
CitedBy_id crossref_primary_10_1111_jam_14292
crossref_primary_10_1002_jgh3_12863
crossref_primary_10_4315_0362_028X_JFP_19_443
crossref_primary_10_1021_acs_analchem_1c00899
crossref_primary_10_4315_JFP_20_087
crossref_primary_10_1093_jaoacint_qsz033
crossref_primary_10_4315_JFP_21_384
crossref_primary_10_3390_hygiene3040026
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
DOI 10.5740/jaoacint.16-0311
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
MEDLINE - Academic
DatabaseTitleList CrossRef
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Agriculture
EISSN 1944-7922
EndPage 547
ExternalDocumentID 10_5740_jaoacint_16_0311
28118134
Genre Journal Article
GroupedDBID ---
0R~
29J
36B
5GY
5WD
85S
A8Z
AAIKC
AAMNW
AAPQZ
AAPXW
AARHZ
AAUAY
AAVAP
ABCQX
ABDBF
ABJNI
ABMNT
ABOCM
ABPTD
ABXVV
ACGFO
ACUTJ
ADGKP
ADGZP
ADIPN
ADNWM
ADQBN
ADVEK
AEGXH
AELWJ
AENEX
AETBJ
AFFZL
AFGWE
AIAGR
AJEEA
ALMA_UNASSIGNED_HOLDINGS
ATGXG
BCRHZ
BEYMZ
CGR
CUY
CVF
EAD
EAP
EAS
EBD
ECM
EIF
EJD
EMB
EMK
EMOBN
ESTFP
ESX
F5P
FHSFR
FLUFQ
FOEOM
GAUVT
H13
I-F
IAG
IAO
IGS
INR
JQ1
KBUDW
KOP
KSI
KSN
L7B
ML-
NOMLY
NPM
OBOKY
OJZSN
OWPYF
OXVGQ
P2P
PV9
ROX
RUSNO
RZL
SV3
TUS
YXANX
AASNB
AAYXX
CITATION
7X8
AGINJ
ID FETCH-LOGICAL-c299t-de97b8e5652af63b09f5e1857f0b9b99893b4b2151034c2ec731435cf01711283
ISSN 1060-3271
IngestDate Fri Aug 16 06:23:18 EDT 2024
Thu Sep 26 18:47:36 EDT 2024
Wed Oct 16 00:47:21 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 2
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c299t-de97b8e5652af63b09f5e1857f0b9b99893b4b2151034c2ec731435cf01711283
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 28118134
PQID 1861853398
PQPubID 23479
PageCount 11
ParticipantIDs proquest_miscellaneous_1861853398
crossref_primary_10_5740_jaoacint_16_0311
pubmed_primary_28118134
PublicationCentury 2000
PublicationDate 2017-03-01
PublicationDateYYYYMMDD 2017-03-01
PublicationDate_xml – month: 03
  year: 2017
  text: 2017-03-01
  day: 01
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Journal of AOAC International
PublicationTitleAlternate J AOAC Int
PublicationYear 2017
SSID ssj0041602
Score 2.2397854
Snippet The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless...
Abstract The AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from...
SourceID proquest
crossref
pubmed
SourceType Aggregation Database
Index Database
StartPage 537
SubjectTerms Adenosine Triphosphate - analysis
Benzalkonium Compounds - chemistry
Decanoic Acids - chemistry
Fatty Acids - chemistry
Hygiene
Limit of Detection
Luciferases - chemistry
Luminescent Measurements
Pseudomonas aeruginosa - isolation & purification
Saccharomyces cerevisiae - isolation & purification
Sanitation
Sodium Hypochlorite - chemistry
Stainless Steel - analysis
Staphylococcus aureus - isolation & purification
Title Validation of the AccuPoint Advanced ATP Hygiene Monitoring System for Sanitation Monitoring Through Detection of ATP from Stainless Steel Surfaces
URI https://www.ncbi.nlm.nih.gov/pubmed/28118134
https://search.proquest.com/docview/1861853398
Volume 100
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb5tAEF65zqU9VH3HfWkr9VJFuLAsjz3ipKlV9RHFTpQbgvUSRYqgoviQ_o3-pf6wzrC7gK1aanpB1goN4O9j5mN3ZpaQtzHEIE9hf7tAMAcTGNEPSoetFGdccSXa-Y4vX8P5Gf90EVyMRr8HWUvrJp_Kn3-tK_kfVGEMcMUq2Vsg2xmFAfgN-MIREIbjP2F8DiJ61Wm-tkhEyvVJdVViV1yzuJ8sTw7mN5fwCts3uE25063K2yzDBbbA0GYGJyzNDj5HqlHSXgONtRUpC5xSuEY3uWiUugYHVBeY3bVL7H5LDjdnHy3S51dZo6cMTm96pn6sM43-wWfcla2bB8pqk3F62qcPLHDDTj06q20ej5nIgODYZXIZ3-uGEBKY3pFlqvSY4NyJBNt02K47YCYbuN9AN5AxkTzQvTy3g0QQcbfdnKDKJOAx9UK4E-PxN_pxb8XJLnsRvpvQRmotpF6YooU7ZI9FIgjGZC-ZHc2OrSIAzWtyX80D6uVytPF--y425dGOb55W-ywfkPsGR5poBj4kI1U-IveSy9o0blGPya-ei7QqKHCRdlyklosU6EMNF2lPNaq5SIGLtOfi8ATDRdpxEa-BxpCLtOMibblILRefkLPjD8vDuWM2_HAkqKLGWSkR5TF4joBlRejnrigChc3KCjcXuRCgrXOeo0h1fS6ZkpGPcl8W2PQJhJb_lIzLqlT7hGLTqBBCt7sKsNQcy8s9COU5uCA_yrJiQt7Z_zn9rvu6pLtwnZA3FogUnC-uqGWlqtY_Ui8OUe_6Ip6QZxqhzhqLsabb589vcaUX5G7_Zrwk46Zeq1cgepv8teHUH-cCscM
link.rule.ids 315,786,790,27955,27956
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Validation+of+the+AccuPoint+Advanced+ATP+Hygiene+Monitoring+System+for+Sanitation+Monitoring+Through+Detection+of+ATP+from+Stainless+Steel+Surfaces&rft.jtitle=Journal+of+AOAC+International&rft.au=Viator%2C+Ryan&rft.au=Gray%2C+R+Lucas&rft.au=Sarver%2C+Ron&rft.au=Steiner%2C+Brent&rft.date=2017-03-01&rft.issn=1060-3271&rft.eissn=1944-7922&rft.volume=100&rft.issue=2&rft.spage=537&rft.epage=547&rft_id=info:doi/10.5740%2Fjaoacint.16-0311&rft.externalDBID=n%2Fa&rft.externalDocID=10_5740_jaoacint_16_0311
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1060-3271&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1060-3271&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1060-3271&client=summon