Research on Contact Characteristics of the Foundation for Wind Turbine Generator System

The 3-D FEM numerical model of foundation for wind power turbine generator system is created, based on the platform of ANSYS. The non-linear contact between the foundation stub part and concrete is introduced. The internal mechanical characteristics and laws are studied when the tower structure is b...

Full description

Saved in:
Bibliographic Details
Published inApplied Mechanics and Materials Vol. 63-64; pp. 633 - 636
Main Authors Zhang, Di, Jiang, Li, Xu, Xin Yong
Format Journal Article
LanguageEnglish
Published Zurich Trans Tech Publications Ltd 01.06.2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The 3-D FEM numerical model of foundation for wind power turbine generator system is created, based on the platform of ANSYS. The non-linear contact between the foundation stub part and concrete is introduced. The internal mechanical characteristics and laws are studied when the tower structure is bearing the random direction wind load. The laws of the settlement and deformation of the tower are discussed and the contact status of contact areas is attained. The numerical analysis which considers the contact status and material nonlinearity is more rational. The research results provide the indigenous design and optimization of our nation scientific basis.
Bibliography:Selected, peer reviewed papers from the 2011 International Conference on Mechanical Engineering, Industry and Manufacturing Engineering (MEIME 2011), July 23-24, 2011, Beijing, China
ISBN:9783037851371
3037851376
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.63-64.633