The Prototype of Detector for Registration Neutron Fluxes Initiated by Electrons and Protons of High Energy in the Calorimeter
A prototype of detector for neutron fluxes, induced by electron and proton showers, registration has been designed. Neutron detector (ND) consists of three alternating layers composed of cadmium plates and plastic scintillator. An optimal detector solution based on a mathematical simulation has been...
Saved in:
Published in | Physics procedia Vol. 74; pp. 254 - 260 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Elsevier B.V
2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | A prototype of detector for neutron fluxes, induced by electron and proton showers, registration has been designed. Neutron detector (ND) consists of three alternating layers composed of cadmium plates and plastic scintillator. An optimal detector solution based on a mathematical simulation has been proposed. This article contains technical information and a description of the experiment to determine neutron detection efficiency, as well as experimental and simulation data analysis results. |
---|---|
ISSN: | 1875-3892 1875-3892 |
DOI: | 10.1016/j.phpro.2015.09.224 |