Investigation of Cascade Connection Method to Improve the Insertion Loss of DM Active EMI Filters
In this article, a new kind of cascade connection method of differential mode (DM) active EMI filter (AEF) is put forward. Contrary to the conventional idea, it is found different kinds of cascade AEF connections show different insertion loss (IL). Based upon the mathematical analysis, among the eig...
Saved in:
Published in | IEEE journal of emerging and selected topics in power electronics Vol. 10; no. 1; pp. 1084 - 1094 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Piscataway
IEEE
01.02.2022
The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | In this article, a new kind of cascade connection method of differential mode (DM) active EMI filter (AEF) is put forward. Contrary to the conventional idea, it is found different kinds of cascade AEF connections show different insertion loss (IL). Based upon the mathematical analysis, among the eight potential connection methods, two cascade AEF-connection methods are more effective than the other six methods. The IL is much higher than the others. Therefore, the two effective topologies are further analyzed from several perspectives. And the best topology suiting the practical application is found. Several prototypes are fabricated and tested. Experimental results show good agreement with the theoretical calculation. |
---|---|
ISSN: | 2168-6777 2168-6785 |
DOI: | 10.1109/JESTPE.2021.3112576 |