Rational design of donor-acceptor fluorescent probe for the ratiometric point-of-care testing of human serum albumin

Human serum albumin (HSA) is an important biomarker for chronic kidney disease, cardiovascular disease, and liver disease, yet its measurement is subject to the routine clinical laboratories. Pioneering studies have demonstrated that few of the ratiometric fluorescent probes enable the point-of-care...

Full description

Saved in:
Bibliographic Details
Published inSensors and actuators. B, Chemical Vol. 398; p. 134687
Main Authors Chen, Zihao, Xu, Zhongyong, Qin, Tianyi, Wang, Dagang, Zhang, Shiwei, Lv, Taoyuze, Wang, Lei, Chen, Xiaoqiang, Liu, Bin, Peng, Xiaojun
Format Journal Article
LanguageEnglish
Published Elsevier B.V 01.01.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Human serum albumin (HSA) is an important biomarker for chronic kidney disease, cardiovascular disease, and liver disease, yet its measurement is subject to the routine clinical laboratories. Pioneering studies have demonstrated that few of the ratiometric fluorescent probes enable the point-of-care (POC) testing of HSA with the aid of affordable domestic apparatuses. Still, the lack of choices of fluorophores restricts the development of such assay. In the present work, we propose two design strategies on the typical donor-acceptor fluorescent probe via the structural engineering. The results suggest that replacement of the dimethylamino group in probe by the weaker electron donating thiophene group can effectively tune the fluorescence response to HSA from off-on to ratiometric, ideally suiting for the POC application. The screened fluorescent probe is capable of detecting HSA with the features of fast response (< 10 s), stable output, high sensitivity (limit of detection = 54 nM), tunable detection range, and great anti-interference. Moreover, the ratiometric fluorescence response to HSA can be recorded and analyzed by the portable miniaturized paper-based or 3D-printed devices at the point of need. The success of structural engineering in the present study provides an efficient way to rationally regulate the fluorescence response mode of the donor-acceptor probes. [Display omitted] ●A donor-acceptor-based probe STF for ratiometric detection of HSA is reported.●The relationship between structure and spectroscopic properties of probe is revealed.●STF enables the rapid, sensitive, and selective detection of HSA.●The portable paper-based testing devices and 3D-printed miniaturized devices are integrated.●The point-of-care testing of HSA is achieved.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2023.134687