Assessment of the effectiveness of ultraviolet-C disinfection on transmission of hospital-acquired pathogens from prior room occupants
To evaluate the effectiveness of ultraviolet-C (UV-C) disinfection as an adjunct to standard chlorine-based disinfectant terminal room cleaning in reducing transmission of hospital-acquired multidrug-resistant organisms (MDROs) from a prior room occupant. A retrospective cohort study was conducted t...
Saved in:
Published in | Antimicrobial stewardship & healthcare epidemiology : ASHE Vol. 2; no. 1; p. e110 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
Cambridge University Press
2022
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | To evaluate the effectiveness of ultraviolet-C (UV-C) disinfection as an adjunct to standard chlorine-based disinfectant terminal room cleaning in reducing transmission of hospital-acquired multidrug-resistant organisms (MDROs) from a prior room occupant.
A retrospective cohort study was conducted to compare rates of MDRO transmission by UV-C status from January 1, 2016, through December 31, 2018.
Acute-care, single-patient hospital rooms at 6 hospitals within an academic healthcare system in Pennsylvania.
Transmission of hospital-acquired MDRO infection was assessed in patients subsequently assigned to a single-patient room of a source occupant with carriage of 1 or more MDROs on or during admission. Acquisition of 5 pathogens was compared between exposed patients in rooms with standard-of-care chlorine-based disinfectant terminal cleaning with or without adjunct UV-C disinfection. Logistic regression analysis was used to estimate the adjusted risk of pathogen transfer with adjunctive use of UV-C disinfection.
In total, 33,771 exposed patient admissions were evaluated; the source occupants carried 46,688 unique pathogens. Prior to the 33,771 patient admissions, 5,802 rooms (17.2%) were treated with adjunct UV-C disinfection. After adjustment for covariates, exposed patients in rooms treated with adjunct UV-C were at comparable risk of transfer of any pathogen (odds ratio, 1.06; 95% CI, 0.84-1.32;
= .64).
Our analysis does not support the use of UV-C in addition to post-discharge cleaning with chlorine-based disinfectant to lower the risk of prior room occupant pathogen transfer. |
---|---|