Multiplanar Reformations in the Measurement of Renal Length on CT: Is It Plain Which Plane to Use?
The objective of this study was to determine the accuracy of renal measurement on CT in multiple imaging planes. In this study, three board-certified radiologists retrospectively measured 110 kidneys on CT in 55 consecutive patients. Five measurement methods were used: axial, coronal single image, c...
Saved in:
Published in | American journal of roentgenology (1976) Vol. 205; no. 4; pp. 797 - 801 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.10.2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The objective of this study was to determine the accuracy of renal measurement on CT in multiple imaging planes.
In this study, three board-certified radiologists retrospectively measured 110 kidneys on CT in 55 consecutive patients. Five measurement methods were used: axial, coronal single image, coronal multiimage, sagittal single image, and sagittal multiimage. The coronal database was sent to a postprocessing workstation, and each radiologist performed a maximum renal measurement using a best off-axis plane that was our reference standard. An ANOVA test with repeated measures and posthoc Bonferroni corrected t tests were performed.
The mean differences (± standard error) compared with the reference standard method were as follows: axial, 7.7 ± 0.7 mm; coronal single image, 13.1 ± 1.4 mm; coronal multiimage, 6.4 ± 0.8 mm; sagittal single image, 6.4 ± 0.6 mm; and sagittal multiimage, 2.8 ± 0.3 mm. The reference standard measurement was larger (p < 0.001), whereas the coronal single-image measurement (p ≤ 0.006) was smaller than all other methods. The sagittal multiimage (p ≤ 0.005) was statistically significantly different from all other methods. There were no statistically significant differences among the axial, coronal multiimage, and sagittal single-image methods (p ≥ 0.088).
The single-image coronal method is the least accurate, with an error of approximately 13 mm. The axial, multiimage coronal, and single-image sagittal methods underestimate renal size by approximately 6-8 mm. Multiimage sagittal is the most accurate method for measuring kidneys with an error of approximately 3 mm. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0361-803X 1546-3141 |
DOI: | 10.2214/AJR.14.14248 |