Pneumothoraces Prevented With Use of Electromagnetic Device to Place Feeding Tubes

A US Food and Drug Administration safety letter warned about the risk for pneumothoraces during feeding tube insertion despite the use of electromagnetic placement devices that provide real-time visualization of feeding tube position. To systematically assess pulmonary placement and pneumothoraces i...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of critical care Vol. 29; no. 1; pp. 22 - 32
Main Authors Bourgault, Annette M, Powers, Jan, Aguirre, Lillian
Format Journal Article
LanguageEnglish
Published United States 01.01.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A US Food and Drug Administration safety letter warned about the risk for pneumothoraces during feeding tube insertion despite the use of electromagnetic placement devices that provide real-time visualization of feeding tube position. To systematically assess pulmonary placement and pneumothoraces in CORTRAK-assisted feeding tube insertions. CINAHL, MEDLINE, and Cochrane databases were searched for studies of CORTRAK-assisted feeding tube insertion. Thirty-two studies documenting pulmonary placement and/or complications of feeding tube insertion were found. Operators recognized pulmonary placement on insertion tracings during 202 CORTRAK-assisted feeding tube insertion procedures, resulting in the immediate withdrawal of 199 feeding tubes. One pneumothorax was identified later by radiography. Seven pulmonary placements were not recognized by CORTRAK operators at the time of feeding tube insertion, resulting in 2 pneumothoraces. The incidence of pneumothorax for CORTRAK-assisted feeding tube insertions was 0.02% (3 of 17039). Of the feeding tubes inserted into the pulmonary system - either found during or after the procedure -1.4% (3 of 209) resulted in pneumothoraces (as opposed to the 19% to 28% incidence of pneumothorax for blind feeding tube insertions. Operators recognizing pulmonary placement on CORTRAK insertion tracings may have prevented 97% (202 of 209) of feeding tubes from being inserted farther into the respiratory tract. Feeding tube insertion with an electromagnetic placement device is advantageous over blind feeding tube insertion because the operator can recognize pulmonary placement early and withdraw the feeding tube, thus decreasing the risk of pulmonary complications.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-3
content type line 23
ObjectType-Review-1
ISSN:1062-3264
1937-710X
DOI:10.4037/ajcc2020247