Fixation methods in pediatric cochlear implants: retrospective review of an evolution of 3 techniques

To review 3 techniques of cochlear implant (CI) fixation used by a single surgeon for the fixation of 320 consecutive CIs in a pediatric population and associated complications. Case series with chart review. Tertiary referral children's hospital. Patients receiving CIs between July 1995 and Ju...

Full description

Saved in:
Bibliographic Details
Published inOtolaryngology-head and neck surgery Vol. 144; no. 3; p. 427
Main Authors Alexander, Nathan S, Caron, Eric, Woolley, Audie L
Format Journal Article
LanguageEnglish
Published England 01.03.2011
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:To review 3 techniques of cochlear implant (CI) fixation used by a single surgeon for the fixation of 320 consecutive CIs in a pediatric population and associated complications. Case series with chart review. Tertiary referral children's hospital. Patients receiving CIs between July 1995 and July 2009 were reviewed. Clinical information obtained included age at implant, implant type, duration of follow-up, method of implant fixation (intraosseous suture ligature, prolene mesh with titanium screws, and a small periosteal pocket with periosteal sutures), and postoperative complications of fixation (migration or extrusion). Three hundred twenty consecutive CIs were reviewed: 64 of which were bilateral (42 staged, 22 concurrent). The median age at implantation was 3.6 years (range, 8 months to 20 years). Manufacturers included Cochlear (223) and Advanced Bionics Corporation (97). Median follow-up was 26 months (range, 1 month to 12.7 years). The intraosseous suture ligation method of fixation was used for 182 CIs. Ninety-eight CIs were fixed using a small piece of polypropylene mesh and titanium screws. Forty implants were secured by using a tight periosteal pocket and placing the suture through the periosteum and soft tissue to collar the receiver in a modified well. No complications of device migration or extrusion were noted, nor were there any intracranial complications. Device failure occurred in 13 (4%) patients requiring explantation and reimplantation, but these were unrelated to surgical technique or fixation. This study illustrates that with an evolution toward less invasive and less complex methods of fixation, there has not been an associated increase in fixation-related complications.
ISSN:1097-6817
DOI:10.1177/0194599810390336