Accuracy of surgical guides manufactured with four different 3D printers. A comparative in vitro study

The aim of this study was to assess the accuracy of surgical guides manufactured with four different 3D printers.. Forty-eight surgical guides (BlueSky Plan, BlueSky Bio) were produced using four different 3D printers, with strict adherence to each manufacturer's instructions. The printers used...

Full description

Saved in:
Bibliographic Details
Published inJournal of dentistry Vol. 148; p. 105226
Main Authors Morón-Conejo, Belén, Berrendero, Santiago, Salido, Maria Paz, Zarauz, Cristina, Pradíes, Guillermo
Format Journal Article
LanguageEnglish
Published England Elsevier Ltd 01.09.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim of this study was to assess the accuracy of surgical guides manufactured with four different 3D printers.. Forty-eight surgical guides (BlueSky Plan, BlueSky Bio) were produced using four different 3D printers, with strict adherence to each manufacturer's instructions. The printers used were three digital light processing (DLP) printers (SolFlex170, VC; Nextdent5100, ND, and D30+Rapidshape, RS) and one stereolithographic (SLA) printer (Formlabs3B+, FL). The study evaluated the trueness and precision of the overall surface, the region of interest (RoI) (occlusal and guide zone), the repeatability in several batches, and the guide hole's diameter and xyz axes. The printed guides were digitized and compared with the CAD design control specimen (Control X, Geomagic). Descriptive statistics and Kruskal-Wallis tests with post-hoc Mann-Whitney tests were performed (α=0.05). Differences in trueness and precision were found between groups in the overall zone and RoI (p = 0.00). The ND group demonstrated the highest repeatability. Only the RS group exhibited a comparable guide hole diameter to the master specimen (5.27±2.12 mm; p = 0.104). No statistical differences were observed between groups in the x and z axes. However, in the y-axis, the VC group displayed statistically significant differences (p = 0.01). The results showed that the DLP groups had better overall accuracy, while the SLA group had the best results in the RoI. The manufacturer's workflows demonstrated a high reproducibility between batches in the RoI. The RS group had values most similar values to the guide hole diameter of the master specimen, with minimal deviations in guide hole orientation. Implant position can be affected by the accuracy of the 3D printed surgical guide. Therefore, it is critical to analyze the final dimensions and the direction of the guide hole using available printing technologies.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0300-5712
1879-176X
1879-176X
DOI:10.1016/j.jdent.2024.105226