Comparison of Contrast Enhancement between Bolus-tracking and Test-bolus Methods on Coronary CT Angiography

Purpose: To compare the contrast enhancement between bolus-tracking (BT) and test-bolus (TB) methods in coronary computed tomography angiography (CCTA). Method: We enrolled 300 patients who underwent CCTA by BT (245 mg I/kg main bolus) or TB (77.4 mg I/kg test bolus with 245 mg I/kg main bolus) meth...

Full description

Saved in:
Bibliographic Details
Published inJapanese Journal of Radiological Technology Vol. 76; no. 6; pp. 579 - 585
Main Authors Kikuhara, Yukari, Sato, Tomoyasu, Masuda, Takanori, Matsumoto, Yoriaki, Yoshiura, Takayuki, Kobayashi, Yukie, Yoshida, Masato
Format Journal Article
LanguageJapanese
Published Kyoto Japanese Society of Radiological Technology 2020
Japan Science and Technology Agency
Subjects
Online AccessGet full text
ISSN0369-4305
1881-4883
DOI10.6009/jjrt.2020_JSRT_76.6.579

Cover

More Information
Summary:Purpose: To compare the contrast enhancement between bolus-tracking (BT) and test-bolus (TB) methods in coronary computed tomography angiography (CCTA). Method: We enrolled 300 patients who underwent CCTA by BT (245 mg I/kg main bolus) or TB (77.4 mg I/kg test bolus with 245 mg I/kg main bolus) methods. In group BT (n=150), scanning was started automatically 5-second after contrast enhancement exceeded a predefined threshold of 150 Hounsfield units (HU). In group TB (n=150), TB peak attenuation plus 2-second was used as a delay. We recorded the CT number in the ascending aorta and determined whether the CT number was equivalent in two groups. For the equivalence test, we adopted 70 HU as the equivalence margin. The standard deviation (SD) in the CT number and the rate of patients with an acceptable CT number were compared. We also compared total iodine dose and total dose length product (DLP). Result: The CT number of the ascending aorta was 437.6±68.9 HU in group BT and 438.9±69.7 HU in group TB; the 95% confidence interval for the difference between the groups was from −11.6 to 20.2 HU and within the range of the equivalence margins. The SD of the CT number and the rate of patients with acceptable CT number did not differ significantly between the two groups (p=0.857 and p=0.614, respectively). Total iodine dose in group TB was significantly higher than in group BT (p<0.001), and total DLP was not statistically significant (p=0.197). Conclusion: The contrast enhancement between BT and TB methods in CCTA was equivalent, and the distribution was not significantly different between the two groups.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0369-4305
1881-4883
DOI:10.6009/jjrt.2020_JSRT_76.6.579