Plastic scintillation detectors for precision Time-of-Flight measurements of relativistic heavy ions

Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of dimensions50×50×3^t mm^3and 80×100×3^t mm^3have been set up at the External Target Faci...

Full description

Saved in:
Bibliographic Details
Published inChinese physics C Vol. 41; no. 6; pp. 128 - 133
Main Author 林文健 赵建伟 孙保华 何鎏春 林炜平 刘传业 谷畑勇夫 寺嶋知 田怡 王枫 王萌 张广鑫 章学恒 竺礼华 段利敏 胡荣江 刘忠 鲁辰桂 任培培 盛丽娜 孙志宇 王世陶 王涛峰 徐治国 郑勇
Format Journal Article
LanguageEnglish
Published 01.06.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of dimensions50×50×3^t mm^3and 80×100×3^t mm^3have been set up at the External Target Facility(ETF), Institute of Modern Physics(IMP). Their time, energy and position responses are measured with the~(18)O primary beam at 400 Me V/nucleon. After off-line corrections for walk effect and position, the time resolutions of the two detectors are determined to be 27 ps(σ) and 36 ps(σ), respectively. Both detectors have nearly the same energy resolution of3.1%(σ) and position resolution of about 3.4 mm(σ). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading the RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
Bibliography:11-5641/O4
plastic scintillator, Time-of-Flight, time resolution, walk effect correction
Wen-Jian Lin1, Jian-Wei Zhao1, Bao-Hua Sun1, Liu-Chun He1, Wei-Ping Lin 2 ,Chuan-Ye Liu1, Isao Tanihata1, Satoru Terashima1, Yi Tian1, Feng Wang1,Meng Wang(1,Guang-Xin Zhang1,Xue-Heng Zhang2, Li-Hua Zhu1, Li-Min Duan2, Rong-Jiang Hu2,Zhong Liu2,Chen-Gui Lu2,Pei-Pei Ren2, Li-Na Sheng2, Zhi-Yu Sun2, Shi-Tao Wang2, Tao-Feng Wang2, Zhi-Guo Xu2, Yong Zheng2(1. School of Physics and Nuclear Energy Engineering, Beihang University, Beijing 100191, China ; 2 Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China)
Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of dimensions50×50×3^t mm^3and 80×100×3^t mm^3have been set up at the External Target Facility(ETF), Institute of Modern Physics(IMP). Their time, energy and position responses are measured with the~(18)O primary beam at 400 Me V/nucleon. After off-line corrections for walk effect and position, the time resolutions of the two detectors are determined to be 27 ps(σ) and 36 ps(σ), respectively. Both detectors have nearly the same energy resolution of3.1%(σ) and position resolution of about 3.4 mm(σ). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading the RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
ISSN:1674-1137
0254-3052