Revascularized Giant Aneurysm of the Anterior Communicating Artery after Surgery and Embolization, Occluded by Placement of a Leo+Baby Intracranial Stent A Case Report

Balt (Montmorency, France) recently manufactured the Leo+Baby dedicated intracranial stent for arteries with a calibre between 1.5 and 3.10 mm. We describe a patient with a partially thrombosed giant sacciform aneurysm of the anterior communicating artery treated without success by surgery and coil...

Full description

Saved in:
Bibliographic Details
Published inThe neuroradiology journal Vol. 26; no. 3; pp. 320 - 326
Main Authors Dall'Olio, M., Calbucci, F., Fioravanti, A., Bortolotti, C., Cirillo, L., Princiotta, C., Leonardi, M.
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 01.06.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Balt (Montmorency, France) recently manufactured the Leo+Baby dedicated intracranial stent for arteries with a calibre between 1.5 and 3.10 mm. We describe a patient with a partially thrombosed giant sacciform aneurysm of the anterior communicating artery treated without success by surgery and coil embolization subsequently occluded by placement of a Leo+Baby stent (Balt, Montmorency, France). A 56-year-old man presented with a giant aneurysm in the anterior communicating artery region. Following successive surgical intervention and embolization procedures the patient was referred to us with a revascularized aneurysm measuring 15×9×8 cm. To stabilize the endovascular occlusion a combined treatment was scheduled with coil embolization and stent deployment after dual antiplatelet therapy started five days before the interventional procedure. Treatment was undertaken two weeks later under general anaesthesia and total heparinization. A microcatheter was inserted into the aneurysmal sac and four metal coils were released for a total of 61cm obtaining almost complete occlusion of the aneurysm from the circulation. A Leo+Baby stent (2.5×18 mm) was subsequently deployed across the aneurysm neck. At follow-up angiography two months later the aneurysm appeared substantially excluded from the arterial circulation except for a small portion in the neck. Six months later, four months after suspending antiplatelet therapy, follow-up angiography disclosed the complete exclusion of the aneurysm from the circulation. Deployment of the new ministent through the same microcatheter used to release the coils made the interventional procedure simpler and faster.
Bibliography:ObjectType-Case Study-2
SourceType-Scholarly Journals-1
ObjectType-Feature-4
content type line 23
ObjectType-Report-1
ObjectType-Article-3
ISSN:1971-4009
2385-1996
DOI:10.1177/197140091302600312