Efficiency of a digital electrofulguration system in contaminated root canals in vitro
Abstract Decontamination of the root canal (RC) system is essential for successful endodontic therapy. In this in vitro study, it was evaluated the disinfection potential of an electrofulguration device, the Endox® Endodontic System (EES), in RC infected with Enterococcus faecalis. Sixty-five human...
Saved in:
Published in | Brazilian dental journal Vol. 32; no. 3; pp. 1 - 9 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
01.06.2021
|
Online Access | Get full text |
Cover
Loading…
Summary: | Abstract Decontamination of the root canal (RC) system is essential for successful endodontic therapy. In this in vitro study, it was evaluated the disinfection potential of an electrofulguration device, the Endox® Endodontic System (EES), in RC infected with Enterococcus faecalis. Sixty-five human lower premolars were instrumented with MTwo® system. The specimens were distributed into six experimental groups (n = 10), according to the irrigation protocol: 2% chlorhexidine gel (CHX); CHX + EES; 5.25% sodium hypochlorite (NaOCl); NaOCl + EES; saline solution (SS); and SS + EES. Five specimens were untreated (control). RC samples were collected before (C1) and after EES treatment (C2), after chemo-mechanical preparation (CMP) (C3), and after final EES treatment (C4). All samples were plated for colony forming units (CFU/mL) onto solid media. The data were analyzed by Wilcoxon and Friedman tests for intragroup comparisons and by Kruskal Wallis test followed by Dunn’s test for intergroup comparisons (α = 0.05). Treatment with the EES did not significantly reduce the number of CFU/mL as compared to baseline levels (C1 vs. C2, p> 0.05). After CMP (C3), all groups showed a significantly reduced amount of CFU/mL (p <0.05), with no difference between CHX- and NaOCl-treated samples (p >0.05). Lastly, treatment with the EES following CMP (C4) did not significantly reduce the amount of CFU/mL (C3 vs. C4, p> 0.05). To conclude, the use of the Endox® Endodontic System did not result in considerable bacterial reduction at all operative times, while treatment with NaOCl and CHX was equally efficient for this purpose.
Resumo A descontaminação do sistema do canal radicular (CR) é essencial para o sucesso da terapia endodôntica. Neste estudo in vitro, foi avaliado o potencial de desinfecção de um dispositivo de eletrofulguração, o Endox® Endodontic System (EES), em CR infectado com Enterococcus faecalis. Sessenta e cinco pré-molares inferiores humanos foram instrumentados com o sistema MTwo®. As amostras foram distribuídas em seis grupos experimentais (n = 10), de acordo com o protocolo de irrigação: clorexidina gel a 2% (CHX); CHX + EES; Hipoclorito de sódio 5,25% (NaOCl); NaOCl + EES; solução salina (SS); e SS + EES. Cinco amostras não foram tratadas (controle). As amostras de CR foram coletadas antes (C1) e após o tratamento com EES (C2), após preparo químico-mecânico (PQM) (C3) e após o tratamento final com EES (C4). Todas as amostras foram plaqueadas para unidades formadoras de colônias (CFU / mL) em meio sólido. Os dados foram analisados pelos testes de Wilcoxon e Friedman para comparações intragrupos e pelo teste de Kruskal Wallis, seguidos pelo teste de Dunn para comparações intergrupos (α = 0,05). O tratamento com o EES não reduziu significativamente o número de CFU / mL em comparação com os níveis basais (C1 vs. C2, p> 0,05). Após PQM (C3), todos os grupos apresentaram uma quantidade significativamente reduzida de CFU / mL (p <0,05), sem diferença entre as amostras tratadas com CHX e NaOCl (p> 0,05). Por fim, o tratamento com o EES após PQM (C4) não reduziu significativamente a quantidade de CFU / mL (C3 vs. C4, p> 0,05). Concluindo, o uso do Endox® Endodontic System não resultou em redução bacteriana considerável em todos os momentos operatórios, enquanto os tratamentos com NaOCl e CHX foram igualmente eficientes para esse fim. |
---|---|
ISSN: | 0103-6440 1806-4760 |
DOI: | 10.1590/0103-6440202104067 |