Field tests with a prototype duplicate microprocessor based governor for a hydro turbine
Field tests have been conducted with a prototype duplicate microprocessor-based governor for a hydro-turbine. The control strategy used in the governor determines the control parameters using an intelligent self-improvement procedure for no-load and loaded conditions. A brief description of the cont...
Saved in:
Published in | IEEE transactions on energy conversion Vol. 6; no. 3; pp. 349 - 355 |
---|---|
Main Authors | , , , , , |
Format | Journal Article Conference Proceeding |
Language | English |
Published |
New York, NY
IEEE
01.09.1991
Institute of Electrical and Electronics Engineers |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Field tests have been conducted with a prototype duplicate microprocessor-based governor for a hydro-turbine. The control strategy used in the governor determines the control parameters using an intelligent self-improvement procedure for no-load and loaded conditions. A brief description of the control strategy and implementation is given, and the results of the field tests are described.< > |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 None |
ISSN: | 0885-8969 1558-0059 |
DOI: | 10.1109/60.84306 |