Comparative Fluoride Ion Release Pre and Postrecharge Situations among Three Different Pediatric Dental Restorative Materials: An In Vitro Study
To determine the initial fluoride (F) release and rerelease after recharge of three pediatric dental restorative materials when aged in artificial saliva (M1) and deionized water (M2). A total of 30 disks, 10 disks of each restorative material R1: Jen Rainbow, Jen Dent Ukraine; R2: Tetric® N-Flow, I...
Saved in:
Published in | International journal of clinical pediatric dentistry Vol. 15; no. 6; pp. 729 - 735 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
India
Jaypee Brothers Medical Publishers
01.11.2022
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | To determine the initial fluoride (F) release and rerelease after recharge of three pediatric dental restorative materials when aged in artificial saliva (M1) and deionized water (M2).
A total of 30 disks, 10 disks of each restorative material R1: Jen Rainbow, Jen Dent Ukraine; R2: Tetric® N-Flow, Ivoclar Vivadent, and R3: resin-modified glass ionomer cement (RMGIC) (Fuji II LC- GC Corporation) were fabricated and were tested for F dynamics in two different media, M1: artificial saliva, M2: deionized water group. The F initial release was measured on the 1st, 7th, 14th, 21st, and 30th day, and on the 31st day, acidulated phosphate F (APF) gel was applied and F rerelease was measured on the 31st, 37th, 44th, 51st, and 60th day using F ion-specific electrode (Orion). The result was statistically analyzed using two-way analysis of variance (ANOVA) and
Bonferroni test.
Fluoride (F) ion release was significantly higher in deionized water than in artificial saliva (M1), and F ion rerelease (after recharge) was significantly higher in artificial saliva (M1). Fuji-II LC demonstrated a significantly (
< 0.05) higher F release and rerelease among all the tested materials. Among the tested composites, R2: Tetric® N-Flow exhibited significantly higher F dynamics than R1: Jen Rainbow composite.
All the tested restorative materials exhibited optimum F release (0.024 ppm, that is, the range to prevent newer carious lesions) in both the pre and postrecharge conditions. Even though Fuji-II LC demonstrated significantly better F dynamics in the tested scenarios, Tetric® N-Flow has the additional advantage of improved mechanical retentive and esthetic properties along with the optimum F release in pre and postrecharge scenarios.
Mathias MR, Rathi N, Bendgude VD,
Comparative Fluoride Ion Release Pre and Postrecharge Situations among Three Different Pediatric Dental Restorative Materials: An
Study. Int J Clin Pediatr Dent 2022;15(6):729-735. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0974-7052 0975-1904 |
DOI: | 10.5005/jp-journals-10005-2461 |