Self-Supervised, Non-Contact Heartbeat Detection Based on Ballistocardiograms Utilizing Physiological Information Guidance

Ballistocardiograms (BCG) is a passive, non-contact heart rate detection technology that requires no action on the part of the individual. However, during the BCG signal acquisition process, the surface pressure generated by cardiac contraction is easily disturbed by external factors, and as people&...

Full description

Saved in:
Bibliographic Details
Published inIEEE journal of biomedical and health informatics Vol. 29; no. 4; pp. 2589 - 2602
Main Authors Jiao, Changzhe, Yang, Aoyu, Zhao, Hantao, Yi, Ruhan, Gou, Shuiping, Sha, Yu, Wen, Wanshun, Jiao, Licheng, Skubic, Marjorie
Format Journal Article
LanguageEnglish
Published United States IEEE 01.04.2025
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Ballistocardiograms (BCG) is a passive, non-contact heart rate detection technology that requires no action on the part of the individual. However, during the BCG signal acquisition process, the surface pressure generated by cardiac contraction is easily disturbed by external factors, and as people's health deteriorates, the j-peak (the main peak of the BCG signal) is no longer prominent. Our aim is to establish a non-contact, self-supervised heart rate detection method based on physiological information, to improve the accuracy and robustness of BCG heart rate detection under wider and more adverse conditions. The algorithm is guided by the heart rate estimation based on BCG itself, thereby reconstructing a signal with physiological significance. We also propose a heartbeat mapping algorithm based on Bidirectional Long Short-Term Memory Network (BiLSTM) for extracting global deep features, achieving real-time heartbeat prediction, and eliminating local deviations brought about by reconstruction. To verify the effectiveness of the proposed method, this paper evaluated 40 young subjects and 4 elderly subjects. Compared with the existing state-of-the-art methods, beat-to-beat heart rate estimation and heartbeat detection both performed excellently, surpassing most methods using precise labels. The experimental results show that the proposed method achieves effective heartbeat detection, demonstrating robustness and effectiveness in the face of unavoidable noise and variations.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2168-2194
2168-2208
2168-2208
DOI:10.1109/JBHI.2024.3509875