Leakage Failure Analysis of High-Pressure Superheater for Waste Heat Boiler of Gas-steam Combined Cycle Unit
Leakage failure of high-pressure superheater for waste heat boiler of gas-steam combined cycle unit was analyzed by metallographic analysis, scanning electron microscope, tensile property analysis and X-ray fluorescence spectrum. The results show that: The main cause of leakage failure of high-press...
Saved in:
Published in | Journal of physics. Conference series Vol. 2360; no. 1; pp. 12007 - 12011 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Bristol
IOP Publishing
01.11.2022
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Leakage failure of high-pressure superheater for waste heat boiler of gas-steam combined cycle unit was analyzed by metallographic analysis, scanning electron microscope, tensile property analysis and X-ray fluorescence spectrum. The results show that: The main cause of leakage failure of high-pressure superheater is under-deposit corrosion caused in long-term operation process. In view of the under-deposit corrosion causes of high-pressure superheater, preventive measures are put forward. |
---|---|