Leakage Failure Analysis of High-Pressure Superheater for Waste Heat Boiler of Gas-steam Combined Cycle Unit

Leakage failure of high-pressure superheater for waste heat boiler of gas-steam combined cycle unit was analyzed by metallographic analysis, scanning electron microscope, tensile property analysis and X-ray fluorescence spectrum. The results show that: The main cause of leakage failure of high-press...

Full description

Saved in:
Bibliographic Details
Published inJournal of physics. Conference series Vol. 2360; no. 1; pp. 12007 - 12011
Main Authors Wei, Shang, Xiaotao, Xia, Kun, Lu, Xinying, Liu
Format Journal Article
LanguageEnglish
Published Bristol IOP Publishing 01.11.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Leakage failure of high-pressure superheater for waste heat boiler of gas-steam combined cycle unit was analyzed by metallographic analysis, scanning electron microscope, tensile property analysis and X-ray fluorescence spectrum. The results show that: The main cause of leakage failure of high-pressure superheater is under-deposit corrosion caused in long-term operation process. In view of the under-deposit corrosion causes of high-pressure superheater, preventive measures are put forward.
ISSN:1742-6588
1742-6596
DOI:10.1088/1742-6596/2360/1/012007