Reproducibility of 18F-FDG microPET Studies in Mouse Tumor Xenografts

(18)F-FDG has been used to image mouse xenograft models with small-animal PET for therapy response. However, the reproducibility of serial scans has not been determined. The purpose of this study was to determine the reproducibility of (18)F-FDG small-animal PET studies. Mouse tumor xenografts were...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of nuclear medicine (1978) Vol. 48; no. 4; pp. 602 - 607
Main Authors Dandekar, Mangal, Tseng, Jeffrey R, Gambhir, Sanjiv S
Format Journal Article
LanguageEnglish
Published United States Soc Nuclear Med 01.04.2007
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:(18)F-FDG has been used to image mouse xenograft models with small-animal PET for therapy response. However, the reproducibility of serial scans has not been determined. The purpose of this study was to determine the reproducibility of (18)F-FDG small-animal PET studies. Mouse tumor xenografts were formed with B16F10 murine melanoma cells. A 7-min small-animal PET scan was performed 1 h after a 3.7- to 7.4-MBq (18)F-FDG injection via the tail vein. A second small-animal PET scan was performed 6 h later after reinjection of (18)F-FDG. Twenty-five sets of studies were performed. Mean injected dose per gram (%ID/g) values were calculated from tumor regions of interest. The coefficient of variation (COV) from studies performed on the same day was calculated to determine the reproducibility. Activity from the second scans performed after 6 h were adjusted by subtracting the estimated residual activity from the first (18)F-FDG injection. For 7 datasets, an additional scan immediately before the second injection was performed, and residual activity from this additional delayed scan was subtracted from the activity of the second injection. COVs of both subtraction methods were compared. Blood glucose values were measured at the time of injection and used to correct the %ID/g values. The COV for the mean %ID/g between (18)F-FDG small-animal PET scans performed on the same day 6 h apart was 15.4% +/- 12.6%. The delayed scan subtraction method did not produce any significant change in the COV. Blood glucose correction increased the COV. The injected dose, tumor size, and body weight did not appear to contribute to the variability of the scans. (18)F-FDG small-animal PET mouse xenograft studies were reproducible with moderately low variability. Therefore, serial small-animal PET studies may be performed with reasonable accuracy to measure tumor response to therapy.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Contributed equally to this work.
ISSN:0161-5505
1535-5667
DOI:10.2967/jnumed.106.036608