Primary System Aerodynamic Characteristics and Associated Circulator Operational Performance of HTR-10
The 10 MW high temperature gas-cooled reactor (HTR-10) has reached its first criticality in 2000 and is currently under testing for full power operation in the near future. The helium circulator test was carried out on both air and helium conditions with the same gas densities of 2.74 kg/m 3 to meas...
Saved in:
Published in | Journal of nuclear science and technology Vol. 40; no. 7; pp. 552 - 557 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
Tokyo
Taylor & Francis Group
01.07.2003
Atomic Energy Society of Japan |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The 10 MW high temperature gas-cooled reactor (HTR-10) has reached its first criticality in 2000 and is currently under testing for full power operation in the near future. The helium circulator test was carried out on both air and helium conditions with the same gas densities of 2.74 kg/m
3
to measure the aerodynamic characteristics of the primary system and the operation performance of the circulator. This paper describes the test procedures and then analyzes the test results. Based on the test data, the aerodynamic characteristics of the primary system and associated operation performance of the circulator under real working condition of the HTR-10 are predicted. As a result, the helium circulator performance satisfies the aerodynamic and operational requirements of the HTR-10 primary system on real working condition by a considerable margin. |
---|---|
ISSN: | 0022-3131 1881-1248 |
DOI: | 10.1080/18811248.2003.9715391 |