Comparative study of permanent magnet synchronous machine vs salient pole synchronous machine in high temperature application

This paper presents the sizing and the comparison of two synchronous machines. The purpose is to design a high temperature dedicated machine with the same performance and volume as a permanent magnet machine. To compare the machines, torque has been chosen as a reference indicator and not the effici...

Full description

Saved in:
Bibliographic Details
Published inEuropean physical journal. Applied physics Vol. 97; p. 52
Main Authors Cousseau, Romain, Romary, Raphaël, Balavoine, François, Irhoumah, Miftah, Pusca, Remus
Format Journal Article
LanguageEnglish
Published EDP Sciences 23.08.2022
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This paper presents the sizing and the comparison of two synchronous machines. The purpose is to design a high temperature dedicated machine with the same performance and volume as a permanent magnet machine. To compare the machines, torque has been chosen as a reference indicator and not the efficiency which will be not so good for the high temperature machine. A salient pole wound rotor is chosen with anodized aluminum tape as windings. Works presented should be considered as preliminary studies leading to the conception of a prototype.
ISSN:1286-0042
1286-0050
DOI:10.1051/epjap/2022210279