Increased R-wave amplitude induced by acute myocardial ischemia in the dog: A predictor of malignant ventricular arrhythmias

The ability of an increase of 25 % or greater in the sum of R-wave amplitudes in leads X, Y, Z, L 2, and V 5 to predict the occurrence of malignant ventricular arrhythmias (10 or more ventricular premature beats/min, ventricular tachycardia [5 or more consecutive premature beats], and/or fibrillatio...

Full description

Saved in:
Bibliographic Details
Published inThe American journal of cardiology Vol. 50; no. 4; pp. 844 - 848
Main Authors David, Daniel, Michelson, Eric L., Naito, Masahito, Schaffenburg, Mark, Dreifus, Leonard S.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.10.1982
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The ability of an increase of 25 % or greater in the sum of R-wave amplitudes in leads X, Y, Z, L 2, and V 5 to predict the occurrence of malignant ventricular arrhythmias (10 or more ventricular premature beats/min, ventricular tachycardia [5 or more consecutive premature beats], and/or fibrillation) was evaluated in 17 dogs during experimental acute myocardial ischemia. Each dog underwent a 15 minute ligation of the left anterior descending coronary artery followed by reperfusion and after recovery, 2 hours later, a 15 minute ligation of the circumflex coronary artery. During ligation of the left anterior descending coronary artery, 12 of 17 dogs (71%) showed no R-wave increase and no arrhythmias (true-negative response). In 5 (29%) of 17 dogs malignant ventricular arrhythmias developed: 2 of 5 (40%) dogs with arrhythmias had a concomitant R-wave increase (true-positive response), and 3 of 5 (60%) with arrhythmias had a less than 25% increase in R-wave amplitude (false-negative results). During circumflex coronary artery ligation, 13 of 17 (76%) dogs showed both R-wave increases and arrhythmias (true-positive response). Four (24%) of 17 dogs had no arrhythmias: 3 of 4 (75%) with no arrhythmias also had a less than 25% increase in R-wave amplitude (true-negative response), whereas 1 of 4 (25%) dogs with no arrhythmias had an increase in R-wave amplitude (false-positive response). In dogs with both arrhythmias and R-wave increases, R-wave changes preceded the onset of arrhythmias by a mean (± standard deviation) of 1 minute 27 seconds (± 43 seconds). Overall, R-wave increases were highly sensitive (83%), specific (94%), and predictive (94%) for the occurrence of malignant ventricular arrhythmias during experimental acute myocardial ischemia.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9149
1879-1913