Multi-interface Level Sensors and New Development in Monitoring and Control of Oil Separators
In the oil industry, huge saving may be made if suitable multi-interface levelmeasurement systems are employed for effectively monitoring crude oil separators andefficient control of their operation. A number of techniques, e.g. externally mounteddisplacers, differential pressure transmitters and ca...
Saved in:
Published in | Sensors (Basel, Switzerland) Vol. 6; no. 4; pp. 380 - 389 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
Basel
MDPI AG
01.04.2006
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | In the oil industry, huge saving may be made if suitable multi-interface levelmeasurement systems are employed for effectively monitoring crude oil separators andefficient control of their operation. A number of techniques, e.g. externally mounteddisplacers, differential pressure transmitters and capacitance rod devices, have beendeveloped to measure the separation process with gas, oil, water and other components.Because of the unavailability of suitable multi-interface level measurement systems, oilseparators are currently operated by the trial-and-error approach. In this paper someconventional techniques, which have been used for level measurement in industry, and newdevelopment are discussed. |
---|---|
ISSN: | 1424-8220 1424-8220 |
DOI: | 10.3390/s6040380 |