Response of a 50kW Organic Rankine Cycle System Subject to Influence of Evaporators

The variations of the evaporator on the system responses of a 50 kWe ORC system using R-245fa are investigated. The effect of exit superheat on the ORC system depends of the types of the evaporator. For the plate evaporator, an exit superheat less than 10°C may cause ORC system unstable due to liqui...

Full description

Saved in:
Bibliographic Details
Published inEnergy procedia Vol. 61; pp. 635 - 638
Main Authors Lee, Yuh-Ren, Kuo, Chi-Ron, Liu, Chih-Hsi, Fu, Ben-Ran, Wang, Chi-Chuan
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 2014
Subjects
Online AccessGet full text
ISSN1876-6102
1876-6102
DOI10.1016/j.egypro.2014.11.1186

Cover

Loading…
More Information
Summary:The variations of the evaporator on the system responses of a 50 kWe ORC system using R-245fa are investigated. The effect of exit superheat on the ORC system depends of the types of the evaporator. For the plate evaporator, an exit superheat less than 10°C may cause ORC system unstable due to liquid entrainment. For maintaining stable operation, the corresponding Jakob number of the plate heat evaporator must be above 0.07. On the other hand, no unstable oscillation of the ORC system is observed for an exit superheat of 0∼17°C when the shell-and-tube heat exchanger is used as the evaporator.