A measurement system for alpha and beta surface emission rate using MWPC
We have developed a large area multi-wire proportional counter (MWPC) as a standard for the measurement of alpha and beta surface emission rate at the Shanghai Institute of Measurement and Testing Technology (SIMT). To shorten the preparation time for chamber gas refilling, a self-designed gas contr...
Saved in:
Published in | Chinese physics C Vol. 39; no. 5; pp. 60 - 63 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.05.2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | We have developed a large area multi-wire proportional counter (MWPC) as a standard for the measurement of alpha and beta surface emission rate at the Shanghai Institute of Measurement and Testing Technology (SIMT). To shorten the preparation time for chamber gas refilling, a self-designed gas control unit was adopted. Various characteristics of the system have been studied. The uncertainties were analysed. Three certified alpha plane sources (Am-241) and six certified beta plane sources (T1-204 and Sr-90/Y-90) were measured by this system, The results show excellent agreement with the surface emission rate reported by the National Institute of Measuring, China (NIM) that En values of all measured sources are within ±1. |
---|---|
Bibliography: | 11-5641/O4 We have developed a large area multi-wire proportional counter (MWPC) as a standard for the measurement of alpha and beta surface emission rate at the Shanghai Institute of Measurement and Testing Technology (SIMT). To shorten the preparation time for chamber gas refilling, a self-designed gas control unit was adopted. Various characteristics of the system have been studied. The uncertainties were analysed. Three certified alpha plane sources (Am-241) and six certified beta plane sources (T1-204 and Sr-90/Y-90) were measured by this system, The results show excellent agreement with the surface emission rate reported by the National Institute of Measuring, China (NIM) that En values of all measured sources are within ±1. LIN Ye, FANG Fang, REN Jia-Fu,HE Lin-Feng, TANG Fang-Dong, XU Yi-He, DING Wei-Cheng(1 Provincial Key Laboratory of Applied Nuclear Techniques in Geosciences, Chengdu University of Technology Dongsanlu, Erxianqiao, Chenghua District, Chengdu 610059, China; 2 Laboratory of Ionizing Radiation, Shanghai Institute of Measurement and Testing Technology, 1500 Zhang Heng Road, Shanghai 201203, China) alpha/beta counting, surface emission rate, plateau curve, MWPC ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1674-1137 0254-3052 |