Deep learning-based fully automatic Risser stage assessment model using abdominal radiographs

Background Artificial intelligence has been increasingly used in medical imaging and has demonstrated expert level performance in image classification tasks. Objective To develop a fully automatic approach for determining the Risser stage using deep learning on abdominal radiographs. Materials and m...

Full description

Saved in:
Bibliographic Details
Published inPediatric radiology Vol. 54; no. 10; pp. 1692 - 1703
Main Authors Hwang, Jae-Yeon, Kim, Yisak, Hwang, Jisun, Suh, Yehyun, Hwang, Sook Min, Lee, Hyeyun, Park, Minsu
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 24.07.2024
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Artificial intelligence has been increasingly used in medical imaging and has demonstrated expert level performance in image classification tasks. Objective To develop a fully automatic approach for determining the Risser stage using deep learning on abdominal radiographs. Materials and methods In this multicenter study, 1,681 supine abdominal radiographs (age range, 9–18 years, 50% female) obtained between January 2019 and April 2022 were collected retrospectively from three medical institutions and graded manually using the United States Risser staging system. A total of 1,577 images from Hospitals 1 and 2 were used for development, and 104 images from Hospital 3 for external validation. From each radiograph, right and left iliac crest patch images were extracted using the pelvic bone segmentation model DeepLabv3 + with the EfficientNet-B0 encoder trained with 90 digitally reconstructed radiographs from pelvic computed tomography scans with a pelvic bone mask. Using these patch images, ConvNeXt-B was trained to grade according to the Risser classification. The model’s performance was evaluated using accuracy, area under the receiver operating characteristic curve (AUROC), and mean absolute error. Results The fully automatic Risser stage assessment model showed an accuracy of 0.87 and 0.75, mean absolute error of 0.13 and 0.26, and AUROC of 0.99 and 0.95 on internal and external test sets, respectively. Conclusion We developed a deep learning-based, fully automatic segmentation and classification model for Risser stage assessment using abdominal radiographs. Graphical Abstract
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1432-1998
0301-0449
1432-1998
DOI:10.1007/s00247-024-05999-1