Curved bridges live load bending moment distribution using straight and curved girders

The present study focuses on comparative parametric analysis of curved precast concrete bridges using straight and curved I-girders. The live load bending moment distribution for girders was studied using the bridge curvature and its relationship with the results obtained for a straight bridge. FEM...

Full description

Saved in:
Bibliographic Details
Published inRevista IBRACON de estruturas e materiais Vol. 15; no. 2
Main Authors Rebouças, Arthur da Silva, Silva Filho, José Neres da, Barros, Rodrigo, Nascimento, Yngrid Rayane Freitas, Coutinho, Pedro Mitzcun
Format Journal Article
LanguageEnglish
Published IBRACON - Instituto Brasileiro do Concreto 2022
Instituto Brasileiro do Concreto (IBRACON)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The present study focuses on comparative parametric analysis of curved precast concrete bridges using straight and curved I-girders. The live load bending moment distribution for girders was studied using the bridge curvature and its relationship with the results obtained for a straight bridge. FEM 3D models were developed with restrictions on the transverse live load positions and with two different load models types: HL-93 (AASHTO) and TB-450 (NBR 7188, 2013). The parametric analysis results were calculated using the Modification Factor (MF) and the Bending Moment Distribution Factor (BMDF), calculated from the structural analysis of each model at the midspan. Globally, an increase was found in the total bending moment for the curved bridge models in relation to the straight bridge. In the examples herein studied, the larger the bending radius, the larger the maximal bending moment in the bridge center. For the external girders, the MF increases with the increase of the L/R. For the internal ones, the MF decreases with the increase of the L/R. In addition, the occurrence of “Load Shift” was different from the rigid body behavior, for there was demonstrated a different bending moment variation between external girder (G1) in relation to its adjacent (G2). Therefore, the structural behavior of straight (SG) and curved girders (CG) was analyzed, revealing that, in the SG, a significant gap occurred in the BMDF between G1 and G2 girders for all curvatures. For L/R = 0.6, it caused a difference of 17.8% in the BMDF between the G1 and G2 girders, while on the curved girders, a difference of only 6.6% was found. resumo: o presente estudo foca na análise paramétrica comparativa de pontes curvas utilizando utilizando longarinas retas e curvas pré-moldadas. As análises foram baseadas na distribuição transversal de momento fletor para a longarinas, na variação da curvatura da ponte e na relação desses parâmetros com os resultados obtidos em uma ponte reta. Foram desenvolvidos FEM 3D models com restrições nas posições transversais da carga-móvel e com dois tipos diferentes de modelos de carga: HL-93 e NBR 7187. Os resultados da análise paramétrica foram determinados utilizando o Fator de Modificação (FM) e o Fator de Distribuição de Momento Fletor (FDMF), calculadas a partir da análise estrutural de cada modelo na posição longitudinal do meio do vão. No âmbito global, contatou-se um aumento do momento fletor total nos modelos de ponte curva em relação à reta. Nos exemplos estudados, quanto maior o raio de curvatura, maior foi o momento fletor máximo no meio do vão da ponte. O valor de FM varia linearmente. Para as longarinas externas o FM aumenta com o aumento do L/R, já para as internas, o FM diminui com o aumento do L/R. Além disso, foi comprovada a ocorrência de “Load Shift” diferente do comportamento de corpo rígido, tendo em vista a variação diferenciada de momento fletor para a longarina externa G1 em relação a sua adjacente G2. Constatou-se uma diferença considerável de comportamento estrutural entre as longarinas retas e curvas, tendo em vista que nas SG ocorreu uma diferença significativa de FDMF entre a longarina G1 e a G2 para todas as curvaturas, o que não ocorreu para as CG. Para L/R=0.6, observou-se uma diferença de 17.8% no FDMF entre as longarinas G1 e G2 retas, já nas longarinas curvas, a diferença foi de apenas 6.6%.
ISSN:1983-4195
1983-4195
DOI:10.1590/s1983-41952022000200008