Influence of Biobrane construction on adherence

Biobrane (standard adherence) and Biobrane L (light adherence) were compared for their degree of adherence to donor site wounds on rabbits at 1, 4, 7, and 9 days. Biobrane, which has more nylon fabric exposed to the wound surface, had significantly greater adherence levels to the wound at all time p...

Full description

Saved in:
Bibliographic Details
Published inJournal of burn care & rehabilitation Vol. 16; no. 3 Pt 1; p. 321
Main Authors Rodeheaver, G T, Hartsell, M L, Faulkner, B C, Major, D A, Foresman, P A
Format Journal Article
LanguageEnglish
Published United States 01.05.1995
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Biobrane (standard adherence) and Biobrane L (light adherence) were compared for their degree of adherence to donor site wounds on rabbits at 1, 4, 7, and 9 days. Biobrane, which has more nylon fabric exposed to the wound surface, had significantly greater adherence levels to the wound at all time periods when compared with Biobrane L, which has less nylon fabric exposed to the wound.
ISSN:0273-8481
DOI:10.1097/00004630-199505000-00019