Novel Extravascular Defibrillation Configuration With a Coil in the Substernal Space

Abstract Objectives This study assessed the defibrillation efficacy of the substernal-lateral electrode configuration. Background Subcutaneous implantable cardioverter-defibrillators (ICDs) are regarded as alternatives to transvenous ICDs in certain subjects. However, substantially higher shock ener...

Full description

Saved in:
Bibliographic Details
Published inJACC. Clinical electrophysiology Vol. 3; no. 8; pp. 905 - 910
Main Authors Chan, Joseph Y.S., MBBS, Lelakowski, Jacek, MD, PhD, Murgatroyd, Francis D., MD, Boersma, Lucas V., MD, PhD, Cao, Jian, PhD, Nikolski, Vladimir, PhD, Wouters, Griet, MSc, Hall, Mark C.S., MD
Format Journal Article
LanguageEnglish
Published Elsevier Inc 01.08.2017
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Objectives This study assessed the defibrillation efficacy of the substernal-lateral electrode configuration. Background Subcutaneous implantable cardioverter-defibrillators (ICDs) are regarded as alternatives to transvenous ICDs in certain subjects. However, substantially higher shock energy of up to 80 J may be required. Proposed is a new defibrillation method of placing the shock coil into the substernal space. Methods This prospective, nonrandomized, feasibility study was conducted in subjects scheduled for midline sternotomy or implant of ICD. A blunted end tunneling tool was used to insert a defibrillation lead behind the sternum using a percutaneous subxiphoid approach. A skin patch electrode was placed on the left mid-axillary line at the fourth to fifth intercostal space. After ventricular fibrillation induction, a single 35-J shock was delivered between the lead and skin patch. Results Sixteen subjects (12 males, 4 females; mean age: 61.6 ± 11.8 years) were enrolled. The mean lead placement time was 11.1 ± 6.6 min. Of the 14 subjects with successfully induced ventricular fibrillation episodes, 13 subjects (92.9%) had successful defibrillation. The 1 failure was associated with high and lateral shock coil placement. Mean ventricular fibrillation duration was 18.4 ± 5.6 s with a shock impedance of 98.1 ± 19.3 ohms. Of the 11 subjects with coil-patch electrograms, the average R-wave amplitude during sinus rhythm was 3.0 ± 1.4 mV. Conclusions These preliminary data demonstrate that substernal defibrillation is feasible and successful defibrillation can be achieved with the shock energy available in current transvenous ICDs. This may open new alternatives to extravascular ICD therapy.
ISSN:2405-500X
2405-5018
DOI:10.1016/j.jacep.2016.12.026