3D FE analysis of the axial forces on the step-up transformer-windings with helicoidal LV
The aim of the paper is to compare the aerial electrodynamic forces on the windings of a large power step-up transformer for three coil designs of the helicoidal LV coil: single layer helix with smoothed or nonsmoothed ends and double layer helix. The evaluation of the axial component of the force i...
Saved in:
Published in | IEEE transactions on magnetics Vol. 31; no. 3; pp. 2032 - 2035 |
---|---|
Main Author | |
Format | Journal Article Conference Proceeding |
Language | English |
Published |
New York, NY
IEEE
01.05.1995
Institute of Electrical and Electronics Engineers |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The aim of the paper is to compare the aerial electrodynamic forces on the windings of a large power step-up transformer for three coil designs of the helicoidal LV coil: single layer helix with smoothed or nonsmoothed ends and double layer helix. The evaluation of the axial component of the force is made after the leakage magnetic field has been computed by a 3D finite element code.< > |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0018-9464 1941-0069 |