Sonographically Observed Echogenic Response During Intraoperative Radiofrequency Ablation of Cirrhotic Livers: Pathologic Correlation

We performed a study to determine the correlation between the diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver and the mean diameter of tissue necrosis. A total of 22 intraoperative radiofrequency ablations were created...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of roentgenology (1976) Vol. 178; no. 5; pp. 1147 - 1151
Main Authors Leyendecker, John R, Dodd, Gerald D., III, Halff, Glenn A, McCoy, Victor A, Napier, Dacia H, Hubbard, Linda G, Chintapalli, Kedar N, Chopra, Shailendra, Washburn, W. Kenneth, Esterl, Robert M, Cigarroa, Francisco G, Kohlmeier, Ruth E, Sharkey, Francis E
Format Journal Article
LanguageEnglish
Published Leesburg, VA Am Roentgen Ray Soc 01.05.2002
American Roentgen Ray Society
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We performed a study to determine the correlation between the diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver and the mean diameter of tissue necrosis. A total of 22 intraoperative radiofrequency ablations were created in 11 cirrhotic livers. The largest diameter of the sonographically observed echogenic response surrounding and perpendicular to the radiofrequency probe was measured. The subsequent zone of necrosis observed at pathology in the hepatectomy specimens after liver transplantation was measured in three planes and compared with the measured diameter of the echogenic response. During all except three ablations, a hyperechoic region was visualized surrounding the radiofrequency probe. The diameter of the echogenic response correlated significantly with the mean diameter of necrosis (correlation coefficient, 0.84). However, the echogenic response overestimated the minimal diameter of necrosis (mean difference, 0.8 +/- 0.4 cm) in 18 of 22 ablations and underestimated the maximum diameter of necrosis (mean difference, 0.9 +/- 0.8 cm) in 16 of 22 ablations. The diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver correlates closely with the mean diameter of the subsequent area of tissue necrosis. However, the solitary diameter of the echogenic response as measured in our study was often greater than the smallest diameter and less than the largest diameter of the area of tissue necrosis. Therefore, the echogenic response associated with radiofrequency ablation of the cirrhotic liver should be viewed only as a rough approximation of the area of induced tissue necrosis; the final assessment of the adequacy of ablation should be deferred to an alternative imaging technique.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0361-803X
1546-3141
DOI:10.2214/ajr.178.5.1781147