A smartphone-based multichannel magnetoelastic immunosensor for acute aortic dissection supplementary diagnosis

Some biomarkers of acute aortic dissection (AAD) can be used for the potential supplementary diagnosis of AAD, such as C-reactive protein (CRP), smooth muscle myosin heavy chain (SmMHC), and D-dimer (D-D). However, the current measurement methods for common markers primarily rely on sophisticated in...

Full description

Saved in:
Bibliographic Details
Published inTalanta (Oxford) Vol. 281; p. 126915
Main Authors Cao, Yunmei, Wang, Qiannan, Han, Mengshu, Zhang, Yunxuan, Yuan, Zhongyun, Zhuo, Kai, Zhang, Hongpeng, Xing, Zhijin, Jin, Hu, Zhao, Chun
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.01.2025
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Some biomarkers of acute aortic dissection (AAD) can be used for the potential supplementary diagnosis of AAD, such as C-reactive protein (CRP), smooth muscle myosin heavy chain (SmMHC), and D-dimer (D-D). However, the current measurement methods for common markers primarily rely on sophisticated instruments. The operation process is complicated, and the reagents used are expensive. To provide chronic disease monitoring and home self-examination services for potential AAD patients in real time, we developed a smartphone-based multichannel magnetoelastic (ME) immunosensing device to detect protein levels. Our immunosensor reduced the aforementioned restrictions and demonstrated excellent performance for the supplementary diagnosis of AAD. In this paper, we successfully combined the intelligent terminal with the hardware system to sample the resonance frequency shift (RFS) on the multichannel ME immunosensor. According to the target detection objects with their respective antibodies in the immune binding response, multiple experiments were conducted to detect multiple groups of samples, and we found that a CRP concentration, a SmMHC concentration, and a D-D concentration in the range of 0.1−100μg/mL, 1−4ng/mL, and 0.25−5μg/mL were linearly proportional to the RFS of the ME immunosensor, respectively. For CRP, SmMHC, and D-D, the sensitivities were 13.37Hz/μg∙mL‐1, 155.19Hz/ng∙mL‐1, and 332.72Hz/μg∙mL‐1, respectively, and the detection limits were 2.634×10‐3μg/mL, 1.155×10‐2ng/mL, and 3.687×10‐3μg/mL, respectively. The experiments demonstrated that the accuracy and stability of our device were comparable to those of the vector network analyzer (VNA, Calibration instrument). [Display omitted] •This paper proposed a new multichannel portable magnetoelastic (ME) immunosensor with high-specificity based on smartphones.•We presented a ME immunosensing device for the supplementary diagnosis of acute aortic dissection (AAD).•In this paper, C-reactive protein (CRP) can be detected with sensitivities of 13.37Hz/μgmL−1.•Smooth muscle myosin heavy chain (SmMHC) can be detected with sensitivities of 155.19Hz/ngmL−1 in this study.•In our research, D-dimer (D-D) can be detected with sensitivities of 332.72Hz/μgmL−1.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0039-9140
1873-3573
1873-3573
DOI:10.1016/j.talanta.2024.126915