On gas-dynamics and heat exchange of flows in cylindrical channels in the presence of heat sources bounded along a longitudinal coordinate

The analysis of energy balance equation for viscous laminar flow of fluid or gas in the cylindrical channel in the area (zone) of warm-up bounded along the longitudinal coordinate is made. It was found that at laminar flow of fluid or gas in a round pipe, in each warm-up area bounded along the longi...

Full description

Saved in:
Bibliographic Details
Published inThermophysics and aeromechanics Vol. 20; no. 4; pp. 429 - 433
Main Authors Gerasimov, A. V., Kirpichnikov, A. P.
Format Journal Article
LanguageEnglish
Published Novosibirsk Kutateladze Institute of Thermophysics SB RAS 2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The analysis of energy balance equation for viscous laminar flow of fluid or gas in the cylindrical channel in the area (zone) of warm-up bounded along the longitudinal coordinate is made. It was found that at laminar flow of fluid or gas in a round pipe, in each warm-up area bounded along the longitudinal coordinate there are the areas of direct and reverse flows separated by a plane that is a locus of points where temperature is maximal for each fixed value of radial coordinate r .