Fluorimetric determination of trace amounts of aluminium and gallium with salicylaldehyde-1-phthalazinohydrazone

Fluorimetric determinations of aluminium and gallium, based on the formation of fluorescence complexes between aluminium(III) or gallium(III) and salicylaldehyde-1-phthalazinohydrazone, SAPhH, are proposed. The aluminium(III)-SAPhH complex exhibited fluorescence with maximal emission at 475 nm when...

Full description

Saved in:
Bibliographic Details
Published inMikrochimica acta (1966) Vol. 109; no. 5-6; pp. 301 - 309
Main Authors GALLEGO, M. C, CALLEJON MOCHON, M, TERNERO RODRIGUEZ, M, GUIRAUM PEREZ, A
Format Journal Article
LanguageEnglish
Published Wien Springer 01.09.1992
New York, NY
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Fluorimetric determinations of aluminium and gallium, based on the formation of fluorescence complexes between aluminium(III) or gallium(III) and salicylaldehyde-1-phthalazinohydrazone, SAPhH, are proposed. The aluminium(III)-SAPhH complex exhibited fluorescence with maximal emission at 475 nm when excited at 414 nm; the gallium(III)-SAPhH chelate had emission and excitation maxima at 480 and 410 nm, respectively. For both determinations, the range of application was 10-100 ng per ml. Aluminium was determined in waters, and gallium in aluminium and nickel alloys. There are 37 references.