Detection and characterization of circulating microvesicles containing Shiga toxin type 2 in a rat model of Hemolytic Uremic Syndrome

Shiga toxin producing Escherichia coli (STEC) are foodborne pathogens that release Shiga toxin (Stx), virulence factor responsible for the development of Hemolytic Uremic Syndrome (HUS). Stx causes endothelial cell damage, which leads to platelets deposition and thrombi formation within the microvas...

Full description

Saved in:
Bibliographic Details
Published inToxicon (Oxford) Vol. 236; p. 107349
Main Authors Sacerdoti, Flavia, Gomez, Fernando D., Jancic, Carolina, Lombardo, Tomas, Pascuale, Carla A., Moretton, Marcela A., Chiappetta, Diego A., Ibarra, Cristina, Amaral, María M.
Format Journal Article
LanguageEnglish
Published 01.12.2023
Online AccessGet full text

Cover

Loading…
More Information
Summary:Shiga toxin producing Escherichia coli (STEC) are foodborne pathogens that release Shiga toxin (Stx), virulence factor responsible for the development of Hemolytic Uremic Syndrome (HUS). Stx causes endothelial cell damage, which leads to platelets deposition and thrombi formation within the microvasculature. It has been described that Stx activates blood cells and induces the shedding of proinflammatory and prothrombotic microvesicles (MVs) containing the toxin. In this sense, it has been postulated that MVs containing Stx2 (MVs-Stx2+) can contribute to the physiopathology of HUS, allowing Stx2 to reach the target organs while evading the immune system. In this work, we propose that circulating MVs-Stx2+ can be a potential biomarker for the diagnosis and prognosis of STEC infections and HUS progression. We developed a rat HUS model by the intraperitoneal injection of a sublethal dose of Stx2 and observed: decrease in body weight, increase of creatinine and urea levels, decrease of creatinine clearance and histological renal damages. After characterization of renal damages, we investigated circulating total MVs and MVs-Stx2+ by flow cytometry at different times after Stx2 injection. Additionally, we evaluated the correlation of biochemical parameters such as creatinine and urea in plasma with MVs-Stx2+. As a result, we found a significant circulation of MVs-Stx2+ at 72 and 96 h after Stx2 injection, nevertheless no correlation with creatinine and urea plasma levels were detected. Our results suggest that MVs-Stx2+ may be an additional biomarker for the characterization and diagnosis of HUS progression. A further analysis is required in order to validate MVs-Stx2+ as biomarker of the disease.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0041-0101
1879-3150
DOI:10.1016/j.toxicon.2023.107349