Characterization of the HCl Absorption & Outgassing Mechanisms by FOUPs' Polymers

The HCl absorption and release by FOUP polymers was characterized through the determination of its solubility and diffusion coefficients in PC and PEEK in clean room conditions (21{degree sign}C and 40% humidity). For the first time, HCl diffusion coefficients were determined (D = 2.9 +/- 1.7 x 10-9...

Full description

Saved in:
Bibliographic Details
Published inECS transactions Vol. 25; no. 5; pp. 139 - 146
Main Authors Fontaine, Hervé, Borde, Yannick, Brych, Christophe, Danel, Adrien
Format Journal Article
LanguageEnglish
Published 01.01.2009
Online AccessGet full text

Cover

Loading…
More Information
Summary:The HCl absorption and release by FOUP polymers was characterized through the determination of its solubility and diffusion coefficients in PC and PEEK in clean room conditions (21{degree sign}C and 40% humidity). For the first time, HCl diffusion coefficients were determined (D = 2.9 +/- 1.7 x 10-9 cm².s-1 in PC and D = 1.4 +/- 0.8 x 10-9 cm².s-1 in PEEK). These experimental data were then applied. First, the HCl concentration profiles in a FOUP's PC wall depending on the contamination time were calculated showing that HCl migrates until 0.5 mm thickness in less than 16h, but also that the full crossing is likely unreachable in an industrial context. Second, the efficiency of usual cleanings were evaluated depending on the temperature or time. For FOUP materials saturated in HCl, relatively low HCl rate (<35%) were determined even for high process temperature.
ISSN:1938-5862