Elucidation of Degradation Factor Distribution in a Same Electrode on PEFC
Our proposal diagnostics evaluates the PEFC's transient response with a resistance polarization, an activation polarization and a diffusion polarization, and derives diagnostics parameters by analyzing this transient response. Because we have already clarified that this diagnostics system was a...
Saved in:
Published in | ECS transactions Vol. 71; no. 1; pp. 107 - 112 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
The Electrochemical Society, Inc
12.02.2016
|
Online Access | Get full text |
Cover
Loading…
Summary: | Our proposal diagnostics evaluates the PEFC's transient response with a resistance polarization, an activation polarization and a diffusion polarization, and derives diagnostics parameters by analyzing this transient response. Because we have already clarified that this diagnostics system was able to diagnose the 25cm2 PEFC single cell, we tried to elucidate the degradation factor distribution in the same electrode by applying it to the quadrisection separator. As a result, our diagnostics was able to judge the difference of the degradation factor in each section in the same electrode such as the resistance polarization is the highest at the gas upper stream, the activation polarization is the lowest at the middle section and the diffusion polarization is the highest at the gas downstream. |
---|---|
ISSN: | 1938-5862 1938-6737 |
DOI: | 10.1149/07101.0107ecst |