Distortional buckling behavior of cold-formed steel built-up closed section columns

In this study, a distortional buckling behavior of cold-formed steel (CFS) built-up closed section columns was revealed and investigated. A total of 12 C-section, 12 U-section, and 24 built-up closed section columns assembled using self-drilling screws at their flanges were tested under concentric a...

Full description

Saved in:
Bibliographic Details
Published inThin-walled structures Vol. 166; p. 108069
Main Authors Li, Yanchun, Zhou, Tianhua, Zhang, Lei, Ding, Jiahao, Zhang, Xingchun
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 01.09.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this study, a distortional buckling behavior of cold-formed steel (CFS) built-up closed section columns was revealed and investigated. A total of 12 C-section, 12 U-section, and 24 built-up closed section columns assembled using self-drilling screws at their flanges were tested under concentric axial compression. The distortional buckling behavior and mechanical properties of the experimental members were investigated, and their buckling modes and failure states were studied. Finite element models were established and verified. The effect of the screw spacing on the distortional buckling behavior and mechanical properties of the CFS built-up columns was explored using three hypothetical models. The results showed the following: I. The number and half-wavelength of the distortional buckling half-waves differ with the variation in the screw spacing. II. When the screw spacing is less than 0.9λc, the ultimate capacities of the CFS built-up columns are greater than the sum of those of the C- and U-section single columns, i.e., the former exhibit the built-up effect (1+1>2). III. When the screw spacing is greater than 0.9λc, the ultimate capacities of the specimens gradually approach the sum of those of two single columns (1+1≈2). Additionally, five different models were proposed to predict the critical load of the distortional buckling. Finally, the ultimate capacities of the built-up columns were calculated using the direct strength method, and it was found that it is conservative to calculate the ultimate capacities of the built-up columns using this method. •Distortional buckling behavior of cold-formed steel (CFS) built-up closed section columns were studied in this paper.•The influences of the screw spacing on the distortional buckling, mechanics characteristic of the kind of columns were studied.•An approach to predict the ultimate strength of the kind of columns was proposed.
ISSN:0263-8231
1879-3223
DOI:10.1016/j.tws.2021.108069