The flow measurement method based on the functional linearizing the dependence of the reaction force on the measured flow rate. Linear reaction flowmeters

There are presented a new worldwide “flow measurement method based on the functional linearizing the dependence of the reaction force on the flow rate”, and the “linear reaction flowmeters” configurations achieved thereof, practically considered “without moving parts”, elaborated by author, the subj...

Full description

Saved in:
Bibliographic Details
Published inMeasurement. Sensors Vol. 38; p. 101581
Main Author Moțit, H.M.
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 01.05.2025
Subjects
Online AccessGet full text
ISSN2665-9174
2665-9174
DOI10.1016/j.measen.2024.101581

Cover

Abstract There are presented a new worldwide “flow measurement method based on the functional linearizing the dependence of the reaction force on the flow rate”, and the “linear reaction flowmeters” configurations achieved thereof, practically considered “without moving parts”, elaborated by author, the subject matter of the patent application filed with European Patent Office, EP 230202582. Thus, the method, based on the initial determination of the analytical expression of k1, the parameter afferent the analytical reaction force FR dependence, on the flow rate Qm, changes the role of k1, from a constant parameter, (afferent the present non - linear reaction flowmeters) to one, variable with Qm−1, by changing the reaction tube outlet, from a constant area nozzle, into one with variable area. Also, using a reaction moment transducer, that measures it developing a balancing moment, proportional to reaction tube angular displacement, is ensured the functional linearizing of FR dependence on Qm. The “linear reaction flowmeters” turndown ensures a quadratic increase of turndown of known reaction flowmeters.
AbstractList There are presented a new worldwide “flow measurement method based on the functional linearizing the dependence of the reaction force on the flow rate”, and the “linear reaction flowmeters” configurations achieved thereof, practically considered “without moving parts”, elaborated by author, the subject matter of the patent application filed with European Patent Office, EP 230202582. Thus, the method, based on the initial determination of the analytical expression of k1, the parameter afferent the analytical reaction force FR dependence, on the flow rate Qm, changes the role of k1, from a constant parameter, (afferent the present non - linear reaction flowmeters) to one, variable with Qm−1, by changing the reaction tube outlet, from a constant area nozzle, into one with variable area. Also, using a reaction moment transducer, that measures it developing a balancing moment, proportional to reaction tube angular displacement, is ensured the functional linearizing of FR dependence on Qm. The “linear reaction flowmeters” turndown ensures a quadratic increase of turndown of known reaction flowmeters.
ArticleNumber 101581
Author Moțit, H.M.
Author_xml – sequence: 1
  givenname: H.M.
  surname: Moțit
  fullname: Moțit, H.M.
  email: hmotit@aair.org.ro
  organization: A.A.I.R.(Control and Instrumentation Association of Romania), Str. Irimicului no.3, bl.3, ap.114, Bucharest, 021142, Romania
BookMark eNp9UN1OwyAYJWYmzrk38IIXaAVKa3tjYhb_kiXezGtC4cOxdLBAp9FH8WmlrRe78oqP850fOJdo5rwDhK4pySmh1c0u34OM4HJGGB-gsqZnaM6qqswaestnJ_MFWsa4I4SwOhEZn6OfzRaw6fwnHlyOAfbg-jT3W69xm3w19g73A-noVG-9kx3urAMZ7Ld17-NKwwGcBqcAezMiAeRIxsaHAZ0s_iL0FBhkDzlej14ngrRK8RDiFTo3souw_DsX6O3xYbN6ztavTy-r-3WmGK1o1vKSUgKkoaSqG1MVpq5Y3dZNa1IXzBBeNulCNAWtikaz9H0DjaTcaE50USwQn3xV8DEGMOIQ7F6GL0GJGCoWOzFVLIaKxVRxkt1NMkhv-7AQRFR26EDbAKoX2tv_DX4BluKKpw
ContentType Journal Article
Copyright 2024
Copyright_xml – notice: 2024
DBID 6I.
AAFTH
AAYXX
CITATION
DOI 10.1016/j.measen.2024.101581
DatabaseName ScienceDirect Open Access Titles
Elsevier:ScienceDirect:Open Access
CrossRef
DatabaseTitle CrossRef
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 2665-9174
ExternalDocumentID 10_1016_j_measen_2024_101581
S2665917424005579
GroupedDBID 0R~
53G
6I.
AAEDW
AAFTH
AALRI
AAXUO
AAYWO
ACVFH
ADCNI
ADVLN
AEUPX
AFJKZ
AFPUW
AIGII
AITUG
AKBMS
AKYEP
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
APXCP
EBS
EJD
FDB
GROUPED_DOAJ
M41
M~E
OK1
ROL
AAYXX
CITATION
ID FETCH-LOGICAL-c2161-b45110e0910689f63f8628b89bf0152f045989b0d1edc39d2000fe9a14fd40d33
ISSN 2665-9174
IngestDate Wed Jul 16 16:48:18 EDT 2025
Sat Aug 16 17:02:35 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Keywords Linearizer
Reaction flowmeters
Turndown increase
Functional linearizing
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c2161-b45110e0910689f63f8628b89bf0152f045989b0d1edc39d2000fe9a14fd40d33
OpenAccessLink http://dx.doi.org/10.1016/j.measen.2024.101581
ParticipantIDs crossref_primary_10_1016_j_measen_2024_101581
elsevier_sciencedirect_doi_10_1016_j_measen_2024_101581
PublicationCentury 2000
PublicationDate May 2025
2025-05-00
PublicationDateYYYYMMDD 2025-05-01
PublicationDate_xml – month: 05
  year: 2025
  text: May 2025
PublicationDecade 2020
PublicationTitle Measurement. Sensors
PublicationYear 2025
Publisher Elsevier Ltd
Publisher_xml – name: Elsevier Ltd
References International Flow Measurement Conference Lisbon, Portugal).
Moțit (bib1) 2020
Moțit (bib3) 2022
H.M. Moțit, A method of flow measurement based on the reaction force. Reaction Flowmeters (FLOMEKO 2019 - 18
Moțit (10.1016/j.measen.2024.101581_bib3) 2022
Moțit (10.1016/j.measen.2024.101581_bib1) 2020
10.1016/j.measen.2024.101581_bib2
References_xml – reference: H.M. Moțit, A method of flow measurement based on the reaction force. Reaction Flowmeters (FLOMEKO 2019 - 18
– year: 2020
  ident: bib1
  article-title: Computer - Implemented Method for Unitary Synthesis and .Design of Flowmeters and of Compound Gauging Structures, European Patent EP 3364159
– reference: International Flow Measurement Conference Lisbon, Portugal).
– start-page: 24
  year: 2022
  end-page: 25
  ident: bib3
  article-title: Fundamentals of Reaction Flowmeters
– start-page: 24
  year: 2022
  ident: 10.1016/j.measen.2024.101581_bib3
– ident: 10.1016/j.measen.2024.101581_bib2
– year: 2020
  ident: 10.1016/j.measen.2024.101581_bib1
SSID ssj0002810124
Score 2.290468
Snippet There are presented a new worldwide “flow measurement method based on the functional linearizing the dependence of the reaction force on the flow rate”, and...
SourceID crossref
elsevier
SourceType Index Database
Publisher
StartPage 101581
SubjectTerms Functional linearizing
Linearizer
Reaction flowmeters
Turndown increase
Title The flow measurement method based on the functional linearizing the dependence of the reaction force on the measured flow rate. Linear reaction flowmeters
URI https://dx.doi.org/10.1016/j.measen.2024.101581
Volume 38
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9wwELYovXCpiigqhSIf4LRKlHWePraIaoWUnkDiFq1fUhEkVVmExKE_pL-WGT_itKxQ4RLtOvHYm_l2PGPPg5AjIzRjQrJEyqZKClFmCed1nsi6lPlcLDkrMRq5_V4tLoqzy_IyHhfY6JKVSOXD2riS13AV2oCvGCX7As6ORKEBPgN_4Qochut_89hcD_ezm7jT52tCz3B5Uv4oYIarl9_0Q7US7OOHECYVquDK0V0A1EgZPBCx1ZHwQyg3ICaYSNGgxzxAsQPcukH_mtupztvGyaUgm_rbIZ4gtcPxSXPMv_6wa8EibdPpNgQro9Ofk1aw0GPRR1dyJ9Vr2ry4dclcvLwEgVC6ki1PRLnbVbhK8edpzFTLijQ-_nfm7H9WtNHPMLiwXXWOSodUOkflDXnL6toe7be_474csxnP0BlhnH2IuLRugU-ns16jmWgp5-_JO29e0C8OK9tkQ_c75A_ghCJv6AQn1OGEWpzQoacrfGjECZ3gxN6KOKGDsS2B7dTiJJAIOHEDWpxQh5NJhxEnH8jFt9Pzk0Xia3IkkoFxkAjMZ5dp1DKrhpsqN2ASN6LhwsDLYAYsBA5fMjXXSuZcYSSY0Xw5L4wqMpXnu2SzH3r9kdBMgTaJFnvJdKF4sSyLSkMXMCCWbJ7XeyQJ77X76VKvdM8xdI_U4eV3Xn10amEHkHq256cXjrRPtuJf4IBsrn7d6c-gm67Eod3TObSQegRP6JLt
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+flow+measurement+method+based+on+the+functional+linearizing+the+dependence+of+the+reaction+force+on+the+measured+flow+rate.+Linear+reaction+flowmeters&rft.jtitle=Measurement.+Sensors&rft.au=Mo%C8%9Bit%2C+H.M.&rft.date=2025-05-01&rft.issn=2665-9174&rft.eissn=2665-9174&rft.volume=38&rft.spage=101581&rft_id=info:doi/10.1016%2Fj.measen.2024.101581&rft.externalDBID=n%2Fa&rft.externalDocID=10_1016_j_measen_2024_101581
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2665-9174&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2665-9174&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2665-9174&client=summon