Radiation Shielding for Medical Compact Cyclotron
We are using a medical compact cyclotron for PET (positron emission tomography) and PIXE (particle induced X-ray emission) analysis in Nishina Memorial Cyclotron Center. The cyclotron vault is covered by concrete wall of 1.5 m thickness. However, a big penetrating window of 1.8 m square was needed a...
Saved in:
Published in | RADIOISOTOPES Vol. 42; no. 2; pp. 97 - 102 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | Japanese |
Published |
Japan Radioisotope Association
1993
|
Subjects | |
Online Access | Get full text |
ISSN | 0033-8303 1884-4111 |
DOI | 10.3769/radioisotopes.42.97 |
Cover
Summary: | We are using a medical compact cyclotron for PET (positron emission tomography) and PIXE (particle induced X-ray emission) analysis in Nishina Memorial Cyclotron Center. The cyclotron vault is covered by concrete wall of 1.5 m thickness. However, a big penetrating window of 1.8 m square was needed at the concrete wall between the cyclotron vault and the PIXE room for beam transport equipment. This window was closed by packing materials of iron shots, small grained polyethylenes mixed with boron and lead grains for shielding of neutrons and γ-rays. Several measurement data have showed that this method is useful for shielding of radiations from the compact cyclotron. |
---|---|
ISSN: | 0033-8303 1884-4111 |
DOI: | 10.3769/radioisotopes.42.97 |