Heat and Moisture Modelling of Vacuum Insulated Retrofits with Experimental Validation

Abstract Vacuum insulation panels (VIPs) offer 8-10 times the thermal resistance of fiberglass insulation and would fit the need for a low conductivity exterior insulation. A composite insulation panel using VIPs encased in rigid foam was developed, built, and tested. Two different sizes of VIPs wer...

Full description

Saved in:
Bibliographic Details
Published inJournal of physics. Conference series Vol. 2069; no. 1; pp. 12035 - 12042
Main Authors Conley, B, Cruickshank, C A, Baldwin, C
Format Journal Article
LanguageEnglish
Published IOP Publishing 01.11.2021
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Vacuum insulation panels (VIPs) offer 8-10 times the thermal resistance of fiberglass insulation and would fit the need for a low conductivity exterior insulation. A composite insulation panel using VIPs encased in rigid foam was developed, built, and tested. Two different sizes of VIPs were used for that stage of the project, and after monitoring and evaluation, they showed contrasting results. A simulation study was performed to find the optimal VIP solution that maximized the effective thermal conductivity and minimized the mould growth potential. In total, 5 wall assemblies with VIPs used as the exterior insulation were simulated using WUFI and WUFI2D. The simulations showed that the humidity levels at the inside face of the OSB inboard of the VIPs decreased when 200 mm by 300 mm VIPs were used, but they did not reach the thermal performance thresholds of R5.28 m 2 K/W. The hygrothermal analysis showed that under similar conditions, a VIP insulated wall assembly would have a lower relative humidity at the sheathing surface compared to EPS and XPS. The one-and two-dimensional simulations were compared and found that WUFI Pro was capable to evaluate a VIP-insulated wall assembly.
ISSN:1742-6588
1742-6596
DOI:10.1088/1742-6596/2069/1/012035