Synovial fluid alpha-defensin in periprosthetic knee infection workup : liquid chromatography-mass spectrometry detection of alpha-defensin in synovial fluid

AIMSThe diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference metho...

Full description

Saved in:
Bibliographic Details
Published inThe bone & joint journal Vol. 104-B; no. 9; pp. 1047 - 1051
Main Authors Balato, Giovanni, Dall'Anese, Riccardo, Balboni, Fiamma, Ascione, Tiziana, Pezzati, Paola, Bartolini, Giuseppe, Quercioli, Massimo, Baldini, Andrea
Format Journal Article
LanguageEnglish
Published 01.09.2022
Online AccessGet full text

Cover

Loading…
More Information
Summary:AIMSThe diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid. METHODSBetween October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy. RESULTSThe AUC was 0.99 (95% confidence interval (CI) 0.98 to 1.00). Receiver operating characteristic (ROC) analysis showed that the optimal cut-off value of synovial fluid alpha-defensin was 1.0 μg/l. The sensitivity of alpha-defensin was 100% (95% CI 96 to 100), the specificity was 97% (95% CI 90 to 98), the positive predictive value was 89.2% (95% CI 82 to 94), and negative predictive value was 100% (95% CI 96 to 100). ROC analysis demonstrated an AUC of 0.99 (95% CI 0.98 to 1.0). CONCLUSIONThe present study confirms the utility of alpha-defensin in the synovial fluid in patients with painful TKA to select cases of PJI. Since LC-MS is still a time-consuming technology and is available in highly specialized laboratories, further translational research studies are needed to take this evidence into routine procedures and promote a new diagnostic approach.Cite this article: Bone Joint J 2022;104-B(9):1047-1051.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2049-4408
DOI:10.1302/0301-620X.104B9.BJJ-2021-1672.R1