A 2‐Phase Merge Filter Approach to Computer‐Aided Detection of Breast Tumors on 3‐Dimensional Ultrasound Imaging
Objectives The role of image analysis in 3‐dimensional (3D) automated breast ultrasound (ABUS) images is increasingly important because of its widespread use as a screening tool in whole‐breast examinations. However, reviewing a large number of images acquired from ABUS is time‐consuming and sometim...
Saved in:
Published in | Journal of ultrasound in medicine Vol. 39; no. 12; pp. 2439 - 2455 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Hoboken, USA
John Wiley & Sons, Inc
01.12.2020
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Objectives
The role of image analysis in 3‐dimensional (3D) automated breast ultrasound (ABUS) images is increasingly important because of its widespread use as a screening tool in whole‐breast examinations. However, reviewing a large number of images acquired from ABUS is time‐consuming and sometimes error prone. The aim of this study, therefore, was to develop an efficient computer‐aided detection (CADe) algorithm to assist the review process.
Methods
The proposed CADe algorithm consisted of 4 major steps. First, initial tumor candidates were formed by extracting and merging hypoechoic square cells on 2‐dimensional (2D) transverse images. Second, a feature‐based classifier was then constructed using 2D features to filter out nontumor candidates. Third, the remaining 2D candidates were merged longitudinally into 3D masses. Finally, a 3D feature‐based classifier was used to further filter out nontumor masses to obtain the final detected masses. The proposed method was validated with 176 passes of breast images acquired by an Acuson S2000 automated breast volume scanner (Siemens Medical Solutions USA, Inc., Malvern, PA), including 44 normal passes and 132 abnormal passes containing 162 proven lesions (79 benign and 83 malignant).
Results
The proposed CADe system could achieve overall sensitivity of 100% and 90% with 6.71 and 5.14 false‐positives (FPs) per pass, respectively. Our results also showed that the average number of FPs per normal pass (7.16) was more than the number of FPs per abnormal pass (6.56) at 100% sensitivity.
Conclusions
The proposed CADe system has a great potential for becoming a good companion tool with ABUS imaging by ensuring high sensitivity with a relatively small number of FPs. |
---|---|
Bibliography: | This work was supported by the Ministry of Science and Technology of Taiwan (grant NSC 99‐3114‐B‐002‐007). All of the authors of this article have reported no disclosures. The described work was presented at the 35th Anniversary and 2019 Annual Convention of the Taiwan Society of Ultrasound in Medicine; held on October 19 and 20, 2019 in Taipei, Taiwan. Ling‐Ying Chiu and Wen‐Hung Kuo contributed equally in this work. ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0278-4297 1550-9613 1550-9613 |