Effect of Ballast Region on Glow Discharge Parameters at Medium and High Pressures

The behavior of a glow discharge in a cylindrical tube with an attached buffer ballast gas region is studied in the pressure range from 10 to 400 Torr. The current–voltage characteristics of a glow discharge in a tube are obtained taking into account the effect of various volumes of the buffer balla...

Full description

Saved in:
Bibliographic Details
Published inHigh temperature Vol. 60; no. 2; pp. 143 - 147
Main Authors Fadeev, S. A., Saifutdinov, A. I., Kashapov, N. F., Saifutdinova, A. A.
Format Journal Article
LanguageEnglish
Published Moscow Pleiades Publishing 01.04.2022
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The behavior of a glow discharge in a cylindrical tube with an attached buffer ballast gas region is studied in the pressure range from 10 to 400 Torr. The current–voltage characteristics of a glow discharge in a tube are obtained taking into account the effect of various volumes of the buffer ballast region. It is shown that, by varying the volume of the buffer ballast area, it is possible to change E / N parameter and discharge current density.
ISSN:0018-151X
1608-3156
DOI:10.1134/S0018151X22020043