More Information
Summary:A novel structure for a charge pump circuit is proposed, in which the charge-pump (CP) current can adaptively regulated according to phase-locked loops (PLL) frequency synthesis demand. The current follow technology is used to make perfect current matching characteristics, and the two differential inverters are implanted to increase the speed of charge pump and decrease output spur due to theory of low voltage difference signal. Simulation results, with 1st silicon 0. 25μm 2. 5 V complementary metal-oxide-semiconductor (CMOS) mixed-signal process, show the good current matching characteristics regardless of the charge pump output voltages.
Bibliography:phase offset
TP331
phase-locked loop
phase frequency detector
low voltagedifference signal
charge pump
current matching
42-1405/N
phase-locked loop; charge pump; phase offset;phase frequency detector; current matching;low voltagedifference signal
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1007-1202
1993-4998
DOI:10.1007/BF02832132