Aortic Valve Replacement and Intraoperative Plasma Exchange in a Patient with Hyperbilirubinemia
We perfomed an aortic valve replacement and intraoperative plasma exchange with Cell Saver 4® made by Haemonetics for removal of bilirubin. Diluted blood after cardiopulmonary bypass and suctioned blood (total volume 11, 300ml) was washed, concentrated and transfused. Plasma bilirubin level was decr...
Saved in:
Published in | Japanese Journal of Cardiovascular Surgery Vol. 20; no. 9; pp. 1533 - 1535 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | Japanese |
Published |
The Japanese Society for Cardiovascular Surgery
1991
|
Online Access | Get full text |
Cover
Loading…
Summary: | We perfomed an aortic valve replacement and intraoperative plasma exchange with Cell Saver 4® made by Haemonetics for removal of bilirubin. Diluted blood after cardiopulmonary bypass and suctioned blood (total volume 11, 300ml) was washed, concentrated and transfused. Plasma bilirubin level was decreased to 5.4mg/dl from 9.9mg/dl during operation. It was concluded that intraoperative plasma excange with Cell Saver 4® was safe and effective technique for removal of bilirubin during open heart surgery. |
---|---|
ISSN: | 0285-1474 1883-4108 |
DOI: | 10.4326/jjcvs.20.1533 |