Methane-Enriched Custodiol Preservation Solution Improves Graft Function in Experimental Model of Heterotopic Heart Transplantation

The key goal of cold storage is to maintain cell viability for a prolonged time during solid organ transplantation. Methane (CH4) has been recognized as novel therapeutic gas exerting anti-inflammatory effects in ischemia-reperfusion (IR) injuries. We aimed to investigate whether cold storage of don...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of heart and lung transplantation Vol. 39; no. 4; pp. S351 - S352
Main Authors Benke, K., Ruppert, M., Sayour, A.A., Jász, D., Szilágyi, Á., Tuboly, E., Baráth, B., Márton, A., Boros, M., Hartmann, P., Szabo, G., Hartyánszky, I., Szabolcs, Z., Merkely, B., Radovits, T.
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.04.2020
Online AccessGet full text

Cover

Loading…
More Information
Summary:The key goal of cold storage is to maintain cell viability for a prolonged time during solid organ transplantation. Methane (CH4) has been recognized as novel therapeutic gas exerting anti-inflammatory effects in ischemia-reperfusion (IR) injuries. We aimed to investigate whether cold storage of donor hearts in CH4-enriched Custodiol preservation solution could protect against IR and preserve myocardial function in a rat model of heterotopic heart transplantation (HTX). The hearts of donor Lewis rats were explanted and stored for 1 h in cold Custodiol (CS group, n=12) or in CH4-saturated (0.054 mg/100 ml) Custodiol (CS-CH4 group, n=12). 60 min after HTX left ventricular (LV) pressure-volume relations and coronary blood flow (CBF) were assessed to evaluate early post-transplant graft function. At the end of haemodynamic measurements, samples were taken for qPCR of endoplasmic reticulum (ER) stress and mitochondria-related apoptosis markers (CHOP, GRP78, GSK3β, VLDR, Caspase 3 and 9, Bcl2, Bax), biochemical parameters and mitochondrial functional analysis with high-resolution respirometry (Oxygraph2K, Austria). LV contractility (LV systolic pressure at 120µl of LV volume: 86±6 vs. 57±7mmHg, p=0.01; dP/dtmax: 2326±167 vs. 1583±139mmHg, p=0.007) and active relaxation (dP/dtmin at 120µl of LV volume: -1660±185 vs. -1043±169mmHg, p=0.04) improved significantly after an hour of reperfusion, while alteration of CBF standardized to heart weight (2.11±0.35 vs. 1.13±0.2ml/min/g, p=0.04) was also significantly improved following pretreatment. CS-CH4 storage significantly reduced the transcription of pro-apoptotic proteins and Bcl2/Bax ratios as compared to CS grafts. Increased mitochondrial oxidative phosphorylation, reduced leak respiration and cytochrome c release were demonstrated in response to CS-CH4 preservation. These results might provide reliable evidence for the benefit of CH4-enriched preservation solution during HTX, through a mechanism which involves the inhibition of pro-apoptotic signals. Hence CH4-enriched preservation solution could be a potential cardioprotective agent in the inventory of heart transplantation surgery and other cardiac surgical procedures requiring prolonged cardioplegia.
ISSN:1053-2498
1557-3117
DOI:10.1016/j.healun.2020.01.410