The measurement of deformation rate of flexible container based on constant conductance element in molecular regime

An innovative method using constant conductance element to measure the deformation rate of flexible container was proposed based on the theoretical model of dynamic micro-flow detection. The measurement system of dynamic deformation rate was built by using the semi-flexible container encapsulated wi...

Full description

Saved in:
Bibliographic Details
Published inFlow measurement and instrumentation Vol. 92; p. 102378
Main Authors Wang, Xudi, Wu, Bingxin, Liu, Wenhui, Wang, Lanling, Wang, Hao, Wu, Xiaobin, Cao, Qing, Wu, Jun
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 01.08.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:An innovative method using constant conductance element to measure the deformation rate of flexible container was proposed based on the theoretical model of dynamic micro-flow detection. The measurement system of dynamic deformation rate was built by using the semi-flexible container encapsulated with polyimide film, and a constant conductance element was installed between the flexible container and the pressure stabilizing chamber to provide a constant micro-flow rate. The dynamic differential pressure variation between the inlet and the outlet of the constant conductance element was measured and then the deformation rate of flexible container could be obtained through the iterative calculation of the measured differential pressure change over time. The results show that the deformation rate gradually decreases with the increase of differential pressure. In addition, Boyle's law was used to verify the experimental results of dynamic micro-flow detection method, and it is revealed that the measurement error is less than 11%. Finally, a standard leak element was applied to simulate the leak source of flexible container. The conductance of standard leak element and the leak rate of flexible container have been successfully predicted by using the measured deformation rate. •Dynamic micro-flow method is proposed to measure the deformation rate of flexible container to improve test efficiency.•The dynamic micro-flow deformation rate test system is built, and the deformation rate offlexible container is obtained.•The dynamic expansion verification experiment is designed to verify the correctness of the dynamic micro-flow method.•Flow conductance of the standard leak element is also predicted successfully by using the measured deformation rate.
ISSN:0955-5986
1873-6998
DOI:10.1016/j.flowmeasinst.2023.102378