Effect of SGC on transient evolution of GWI in a Doppler broadened quasi Λ-type four-level system

In this paper,we study the effect of spontaneously generated coherence(SGC) on transient evolution of gain without inversion(GWI) in a Doppler broadened quasi Λ-type four-level atomic system.It is shown that transient evolution of GWI is very sensitive to the variation of SGC strength,and the transi...

Full description

Saved in:
Bibliographic Details
Published inOptoelectronics letters Vol. 8; no. 5; pp. 393 - 396
Main Authors Liu, Zhong-bo, Tong, Dian-min, Fan, Xi-jun
Format Journal Article
LanguageEnglish
Published Heidelberg Tianjin University of Technology 01.09.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this paper,we study the effect of spontaneously generated coherence(SGC) on transient evolution of gain without inversion(GWI) in a Doppler broadened quasi Λ-type four-level atomic system.It is shown that transient evolution of GWI is very sensitive to the variation of SGC strength,and the transient maximum value and steady value of GWI both increase with SGC strength increasing.The transient and steady values of GWI with SGC are much larger than those without SGC.When Doppler broadening is present,the transient maximum value and steady value of GWI first increase and then decrease with Doppler broadening width(D) increasing,and the value of D which corresponds to the maximum transient GWI is different from that corresponding to the maximum steady GWI.The time needed for reaching the steady GWI increases with D increasing.The steady GWI,which is larger than that without Doppler broadening(D = 0),can be obtained by choosing appropriate D and SGC strength.
Bibliography:In this paper,we study the effect of spontaneously generated coherence(SGC) on transient evolution of gain without inversion(GWI) in a Doppler broadened quasi Λ-type four-level atomic system.It is shown that transient evolution of GWI is very sensitive to the variation of SGC strength,and the transient maximum value and steady value of GWI both increase with SGC strength increasing.The transient and steady values of GWI with SGC are much larger than those without SGC.When Doppler broadening is present,the transient maximum value and steady value of GWI first increase and then decrease with Doppler broadening width(D) increasing,and the value of D which corresponds to the maximum transient GWI is different from that corresponding to the maximum steady GWI.The time needed for reaching the steady GWI increases with D increasing.The steady GWI,which is larger than that without Doppler broadening(D = 0),can be obtained by choosing appropriate D and SGC strength.
12-1370/TN
ISSN:1673-1905
1993-5013
DOI:10.1007/s11801-012-2252-3